Ozone generator Airozon® 28 ECO

Setting the treatment intensity

You can set the treatment intensity (stage 1–4) for cleaning the
room as follows:

1. Press the 

Ozone

 button (13) to set the desired ozone

concentration.

ð

The 

Ozone concentration

 LEDs (10) are illuminated.

ð

The 

Ozone stage

 LED (16) indicates the current ozone

stage.

Setting the timer

Using the timer, you can set the treatment duration after which
the device will automatically switch off.

1. Press the 

Timer

 button (18) to set a stopping time of

maximally 135 minutes.

ð

The stopping time can only be selected in increments
of 15 minutes.

ð

The 

Timer

 LED (14) is illuminated.

ð

The 

Hours

 LED (15) is illuminated.

Carrying out an odour neutralization / air purification

Warning
Risk of injury caused by inhalation of ozone!

The following symptoms could be indicative of
poisoning or an irritation caused by ozone:
- eye irritations – conjunctivitis, stinging and watering
eyes
- strong urge to cough
- shortness of breath – chest tightness
- pain while inhaling
- dizziness, light-headedness
- headache
- feeling of faintness
Exit the room to be cleaned immediately after the
device has been switched on.
Do not enter the room whilst the air purification is in
progress.
Should you experience one or more of the above
symptoms relating to the use of the odour neutraliser,
seek medical treatment immediately!

Please proceed as follows to perform an air purification:

1. Seal off all openings of the room to be cleaned. It must be

accomplished in a way to prevent ozone from escaping to
the environment.

2. Attach warnings that indicate the presence of high ozone

concentrations and the related hazards.

3. Make sure that neither humans nor animals are situated in

the room to be cleaned.

4. Position the device in the centre of the room.
5. Connect the power cable and insert the mains plug into a

properly secured mains socket located outside of the room
to be cleaned.

6. Set the desired treatment duration.

7. Switch the device on and select the desired operating

mode.

ð

The cleaning cycle will probably be launched
immediately.

8. Exit the room directly after having started the device.

ð

The ozone generator will now operate until the end of
the set cleaning period. Afterwards it will switch off
automatically.

Operating parameters

The duration of the cleaning process can differ depending on
the conditions. Factors to be taken into consideration include:

Type of exposure

Intensity

Room size and temperature

Material composition of the object to be treated

Exposure time and depth up to which the material has
been affected

If an odour elimination is carried out in an unheated room which
will later be used at higher temperatures, there is a risk of
subsequent evaporation. For this reason the room temperature
should always be approx. 5 °C higher during the purification
process as compared to the later usage temperature.
The values below are to serve as a general reference for the
determination of the treatment duration:

Type of smell

Treatment duration given
in min

Room size
< 30 m³

Room size
30 – 60 m³

Car treatment

40

80

Animal, cooking and waste smells 40

80

Smell of burning / chemicals

80

120

Musty odour after water damage

80

120

Smell of burning and secondary
effects of organic substances

80 – 350

120 – 700

Amines / amides (ureas), open-
chain hydrocarbon compounds
(e.g. butyric acid)

360

720

Amino acids / proteins with
nitrogen and sulphur (vomit)

360

720

Please contact the Trotec customer service if you like to use the
device for disinfection purposes.

Содержание 1180000095

Страница 1: ...TRT BA AIROZON 28ECO TC2020 17 002 EN AIROZON 28 ECO EN ORIGINAL INSTRUCTIONS OZONE GENERATOR ...

Страница 2: ...fore starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above an...

Страница 3: ...eristics can cause severe health damage if inhaled Direct exposure to and intake of ozone is toxic for humans animals and plants For this reason the following safety measures must be observed by all means Once the device has been started as well as during the cleaning process there must be neither people nor animals in the room to be cleaned Also remove any plants Leave the room immediately once t...

Страница 4: ... in an unprofessional or improper way Observe the personnel qualifications Warning The device is not a toy and does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Warning Risk of injury caused by inhalation of ozone The following symptoms could be indicative of poisoning or an irritation caused by ozone...

Страница 5: ...r UV radiation It is these atoms that can react with the oxygen molecules to form ozone O3 In case of a high solar irradiation ozone forms involving other air pollutants The nitrogen oxides NOx from automobiles domestic heating systems power plants and the industry play a major role in this Depending on the concentration ozone can have a very intense smell similar to chlorine hay or carnations odo...

Страница 6: ... the power cable out of the mains socket If the device was previously in use wait until the end of the calculated regeneration period see Shutdown chapter before transporting the device Do not use the power cable to drag the device During transport protect the device against shifting and vibrations to avoid electrode damage After transporting the device proceed as follows Set up the device in an u...

Страница 7: ...ation free ground Position the device as close as possible to the centre of the room to ensure an optimum air circulation When positioning the device keep a sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow Do not position the device near inflammable substances and gases Make sure that the air inlet and outlet are not obstructed Make sure t...

Страница 8: ... setting from 0 135 minutes 19 Power button For switching the device on or off 20 Increase ozone button Press this button to increase the ozone concentration by one stage 21 Decrease ozone button Press this button to decrease the ozone concentration by one stage Switching the device on Warning Risk of injury caused by ozone Exit the room as soon as you have switched the device on so as to prevent ...

Страница 9: ...re that neither humans nor animals are situated in the room to be cleaned 4 Position the device in the centre of the room 5 Connect the power cable and insert the mains plug into a properly secured mains socket located outside of the room to be cleaned 6 Set the desired treatment duration 7 Switch the device on and select the desired operating mode ð The cleaning cycle will probably be launched im...

Страница 10: ...ch off the device by pressing the Power button 19 ð Once you have switched the device off the fan and one of the ozone plates inside the device will keep working for another minute in order to cool the device 2 Hold onto the mains plug while pulling the power cable out of the mains socket 3 Clean the device according to the Maintenance chapter 4 Store the device according to the Storage chapter Er...

Страница 11: ...n humid rooms Regardless of the described operating conditions you should perform maintenance work if one or more of the following signs become apparent increased noise level during operation of the fan heavily contaminated air filter dirty electrode recognizable by The hissing sound produced during ozone generation dies away Cleaning the housing Clean the housing with a soft damp and lint free cl...

Страница 12: ...e refrigeration unit 24 5 Insert the new ozone plate 22 and slightly press it onto the cooling plate 24 6 Screw the housing 2 back on the ozone generator and firmly retighten the screws Technical annex Technical data Parameter Value Model Airozon 28 ECO Electric connection 110 120 V 6 A 50 60 Hz or 220 240 V 3 A 50 60 Hz Frequency 50 Hz Max nominal current 1 5 A Max power input 350 W Ozone output ...

Страница 13: ...EN 13 Ozone generator Airozon 28 ECO Circuit diagram L N E Conrtrol system FAN Ozone Generator Power 1 FU Ozone Generator Power 2 Ozone Generator Power 4 Ozone Generator Power 3 ...

Страница 14: ... Note The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions No Spare part No Spare part 1 handle 6 power seat 2 cover 7 ozone power supply 3 ozone module 8 base 4 stents 9 control module 5 fan ...

Страница 15: ... 2006 on batteries and accumulators Please dispose of batteries and accumulators according to the relevant legal requirements Declaration of conformity The text below sets out the contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 44535 Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Par...

Страница 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Отзывы: