![Trotec 1.580.000.101 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/trotec/1-580-000-101/1-580-000-101_original-instructions-manual_1171629010.webp)
10
EN
air cleaner TAC 750 E
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Visual inspection of the inside of the device for dirt
1. Remove the air filters.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, clean the inside of the
device with a vacuum cleaner.
5. Reinsert the air filters.
Cleaning the inside of the device
1. First remove the filters and the filter frame as described in
the Inserting the filters section in the Assembly and start-
up chapter.
2. Clean the inside of the device and the filter frame with a
soft, damp and lint-free cloth. Make sure that no moisture
enters the housing. Protect electrical components from
moisture. Do not use any aggressive cleaning agents such
as cleaning sprays, solvents, alcohol-based or abrasive
cleaners to dampen the cloth.
3. Reinsert the filters and the filter frame into the device.
Changing the filter
The filter has to be replaced when it is heavily contaminated.
This is brought to light e.g. by a reduced capacity.
If a filter needs to be replaced, please proceed as described in
the Inserting the filters section in the Assembly and start-up
chapter.
Technical annex
Technical data
Parameter
Value
Model
TAC 750 E
Article number
1.580.000.101
Recommended amount of air for
dust class H
290 m
3
/h
Dust class
(as per DIN 60335-2-69)
Dust class H
Max. power input
0.12 kW
Mains connection
1/N/PE ~ 230 V / 50-60 Hz
Nominal current
1 A
Connection cable
CEE 7/7, 3 m cable length
Air transport hose connector inlet/
outlet side
200 mm
Sound level (at a distance of 1 m) 77 dB(A)
Dimensions
(length x width x height)
315 x 430 x 430 mm
Weight
5.5 kg