AMD-53-S2 MODULATOR / MULTIPLEXER
3.11. MODULATOR PARAMETERS
In this menu you need to specify the parameters of the output carrier
:
Output frequency up 900 to 2150MHz;
Symbol Rate up 1000 to 30000 kSymb per Second
Modulation/FEC QPSK: 1/3, 2/5, 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10
8PSK: 3/5, 2/3, 3/4, 5/6, 8/9, 9/10
16APSK: 2/3, 3/4, 4/5, 5/6, 8/9, 9/10
32APSK: 3/4, 4/5, 5/6, 8/9, 9/10
Roll-off
0,2 ; 0,25 ; 0,35
FEC Frame length
Normal/short
Pilot tone
On/off
Spectrum Inversion
On/off
Output attenuation
up -31.5 to 0 dB
RF output
On/Off
The actual bitrate at the output of the modulator is displayed as a blue scale at the top of the menu.
Free capacity of the transponder is filled with zero packets if the subscription data does not come to
the modulator from the billing server. The capacity occupied by zero packets is indicated in the form
of a gray scale.
Free capacity is filled with subscription packages if the billing server sends TROPHY-ACCESS CAS
data to the modulator. The efficiency of data transmission is maximum. The capacity that the
subscription data occupies is indicated in the form of a yellow scale. Thanks to this technology, the
CAS data transmission efficiency is maximum.
Payload rate: 30,155 Mbit (0,94%)
Subs rate: 1,93 Mb
Payload rate: 30,155 Mbit (0,94%)
Subs rate: 0 Mb
Payload rate: 30,155 Mbit (0,94%)
Subs rate: 1,93 Mb