GENERAL (continued)
5.1.3
Mimic Panel Indicators
The following components are represented by light-emitting
diodes (LED’s):
1
Input
2
Static Switch
3
Transformer/Rectifier
4
DC Output
5
Warning (General failure)
The color of the LED’s and whether they are steady or
flashing provides information about the current operating
status of the respective components:
Green flashing:
starting phase
Green steady:
running or switched on
Yellow flashing:
warning
Yellow steady:
available/ready
Red flashing:
fault
Red steady:
abnormal condition, e.g. mains fault, overload
5.1.4
Displays
With push buttons
and
It is possible to display various operating data.
With push buttons
or
It is possible to change to the Event Monitor or into the setup menu. The following figure shows
examples of display screens for converter type 28 VDC GPU 600 A.
4
3
2
1
5
!
Figure 5.1.3
Mimic Display
Figure 5.1.4 – LC Display with Examples
02.JANUAR 97 14:50:37
OPERATION
1234 H
INPUT
19 kW
kW
OUTPUT
16 kW
02. JAN 97 08:53:12:14
Start push-button
contact closed
E205
IN:
16
kVA 50.0 Hz
L1:
400 V
29 A
L2
400 V
29 A
L3
400 V
29 A
+
+
Setup
Password
Output Voltage DC
Output Current DC
or
OUT:
DC
28 V
600 A
or
R
Содержание 11A6647-1000