![background image](http://html1.mh-extra.com/html/tronair/11a6647-1000/11a6647-1000_operation-and-service-manual_1171190030.webp)
28.5 VDC Ground Power Unit
Models:
11A6647-1000/1010
11B6647-1000/1010
11C6647-1000/1010
11D6647-1000/1010
11A6647C1000/1010
11B6647C1000/1010
11C6647C1000/1010
11D6647C1000/1010
11A6655-1000/1020
11B6655-1000/1020
11C6655-1000/1020
11A6655C1000/1020
11B6655C1000/1020
11C6655C1000/1020
11D6655C1000/1020
11A6665-1000/1010
11B6665-1000/1010
11C6665-1000/1010
11A6666-1000
11B6666-1000
11C6666-1000
12/2006 - Rev. 04
- 24 -
4.8
ADDITIONAL EQUIPMENT (continued)
4.8.2
APOMON Remote Control Monitor
Function
The ApoMON is a software application which can run under “MS/Windows™ version 3.x” on
personal computers. With it, it is possible to display the Master Control Panel (MCP) for any
converters connected. Not only an individual Control Panel but also the entire installation can be
displayed to support the converter system.
All parameters and events for each connected converter are displayed on the screen. The
frequency converters and their outputs can also be switched on if the corresponding keys on the
RCP are enabled (see Section 4.8.1).
The total distance of all connections between the converter sets and the PC must not exceed 1.2
km. If longer cables are used, an optional Repeater must be installed. A screened twisted pair
cable 0.4–0.6mm
2
must be used.
At the 28V DC GPU the connecting cable is connected to the Protocol Gateway A260, terminal
strip X1, terminals 1,2 and 5,6. At the PC the cable is connected to the RS485 interface.
4.8.3
Modem Connection APOCONNECT
As an option the converter could be equipped with a modem to make a remote control and
indication via phone line. With this modem the converter could be brought to the expert. With the
internal remote troubleshooting software, a complete diagnostic could be done from the far. It is
only necessary to put in the Set and to connect the Tronair standard cable between protocol
gateway terminal strip X2 and a standard modem and the phone line to the modem. A PCMCIA
modem is also possible. This has to be mounted in slot X7.
The APOCONNECT – Set includes:
•
Protocol gateway
•
Modem Kit
Personal
Computer
(RS485)
28V DC GPU1
optional
Repeater
Maximum
distance
1.2 km
A260
A260
A260
28V DC GPU2
28V DC GPU3
Figure 4.8.2
Connections Between Converter and Remote Control Monitor
Содержание 11A6647-1000
Страница 6: ......
Страница 63: ...APPENDIX I Declaration of Conformity ...
Страница 64: ......
Страница 65: ......