priming so that any air in the intake line can escape. 
Depending  on  the  suction  height  and  the  amount  of  air  in  the  intake  line,  priming  can  take 
anywhere  between  30  seconds  and  5  minutes.  If  it  takes  longer  than  this,  the  pump  should  be 
refilled with water. If the pump is removed again after use, it must always be refilled with water 
whenever it is connected up and used again. 
 

Maintenance instructions 

The pump is basically maintenance free. To ensure a long service life, however, we recommend 
regular checks and care. 

Warning!

 Before every servicing, switch off the pump and remove the plug from the socket. 

If the pump is not going to be used for a long time or has to be removed for the winter months, 
rinse it out with water, empty it completely by unscrewing both vent plugs and allow it to dry.   
If there is a risk of frost, the pump must be emptied complete. 
After  long  stoppages,  make  sure  the  rotor turns  correctly by briefly switching the pump on and 
off.  If  the  pump  becomes  blocked,  connect  the  pressure  line  to  the  water  line  and  remove  the 
intake hose. Open the water line, Switch on the pump several times for approx 2 seconds, Most 
blockages can be removed in this way. 
Regularly maintain your pump and keep the air pressure in tank at 1.5bar. 
 

Fault 

Motor fail to start up 

Cause

Remedies

No mains voltage

Check voltage

Pump rotor blocked-thermostat switched off

Dismantle and clean pump

 

No intake 

Cause

Remedies

Intake valve not in water

Innerse intake valve in water

Pump chamber without water connection

Fill water into intake

Air in intake line air-tight

Make sure the intake line is tightened

Intake valve leaks

Clean intake valve

Strainer (intake valve) blocked

Clean strainer

Max. Suction height exceeded

Check suction height

 

Inadequate delivery rate 

Cause

Remedies

Suction height too high

Check suction height

Strainer dirty

Clean strainer

Water level falling rapidly

Immerse intake valve deeper

Pump performance reduced by contaminants part

Clean pump and replace wearing parts

 

Thermostat switches pump off 

Cause

Remedies

Motor overloaded - friction
caused by substances too high

Dismantle and clean pump.
Prevent intake of foreign 

body

 substances (filter).

 

 

 

“Electrical products must not be thrown out with domestic waste. Recycle them at the special 
disposal centres provided for the purpose. Contact your local authorities or stockist for advice on 
recycling”.

 