SPECIFICATIONS

Flow Rates

Maximum rated flow 

at dose of  16 mJ/cm

@ 70% UVT

______

4.3 GPM

(16.3 LPM)

8.9 GPM

(33.7 LPM)

8.9 GPM

(33.7 LPM)

15.8 GPM

(59.8 LPM)

26.1 GPM

(98.8 LPM)

Maximum rated flow 

at dose of 16 mJ/cm

2

@  85% UVT

3 GPM

(11 LPM)

6 GPM

(23 LPM)

16 GPM

(60 LPM)

16 GPM

(60 LPM)

29 GPM

(110 LPM)

45 GPM

(170 LPM)

Maximum rated flow 

at dose of 30 mJ/cm

2

@  85% UVT

1 GPM

(4 LPM)

4 GPM

(15 LPM)

9 GPM

(34 LPM)

9 GPM

(34 LPM)

15 GPM

(57 LPM)

25 GPM

(95 LPM)

Maximum rated flow 

at dose of 40 mJ/cm

2

@  85% UVT

1 GPM

(4 LPM)

3 GPM

(11 LPM)

7 GPM

(26 LPM)

7 GPM

(26 LPM)

12 GPM

(45 LPM)

20 GPM

(76 LPM)

Electrical

Voltage

120V or  240V AC

100-240V AC

100-240V AC

100-240V AC

100-240V AC

100-240V AC

Frequency

50-60 Hz

50-60 Hz

50-60 Hz

50-60 Hz

50-60 Hz

50-60 Hz

Max. current

0.3 Amp

 0.4 Amp

0.5 Amp

0.5 Amp

0.85 Amp

1.2 Amp

Max. power 

consumption

22 Watts

36 Watts

50 Watts

50 Watts

83 Watts

130 Watts

Lamp power

14 Watts

25 Watts

40 Watts

40 Watts

70 Watts

110 Watts

Other

UV Chamber Material

304 SST

304 SST

304 SST

304 SST

316 SST

316 SST

Inlet/Outlet

3/8" FNPT

3/4" NPT

3/4" NPT

3/4" NPT

1" NPT

1" NPT

A

B4*

C4*

E4/E4 Plus*

F4/F4 Plus*

D4/D4 Plus*

Operating Parameters

Maximum operating pressure

125 PSI (862 kPa)

Minimum operating pressure

 4 PSI (27.5 kPa)

Maximum ambient air temperature

122 

0

F  (50

0

C) 

Minimum ambient air temperature

32

0

F  (0

0

C) 

Maximum humidity

100%

Maximum hardness

120 ppm 

(7 grains per gallon)

Maximum iron

0.3 ppm

Minimum UVT

75%

   Installation

Vertical or horizontal*

Other

Rated service life of lamp

1 year

Certification

General (All Models)

*Systems with sensors must be installed vertically. **Model A is only system certified by CSA and not by UL.

Operating Parameters

Maximum operating pressure

125 PSI (862 kPa)

Minimum operating pressure

 4 PSI (27.5 kPa)

Maximum ambient air temperature

122 

0

F  (50

0

C) 

Minimum ambient air temperature

32

0

F  (0

0

C) 

Maximum humidity

100%

Maximum hardness

120 ppm 

(7 grains per gallon)

Maximum iron

0.3 ppm

Minimum UVT

70%

   Installation

Vertical or horizontal*

Flow Restrictor

Yes

NSF Certification

NSF Standard 55 
Class B

Rated service life of lamp

1 year

Certification (other)

NSF Standard 55 Class B Models (-V)

CARACTÉRIS

TIQUES

Pression de 

fonctionnement maximale

125 lb/po² (862

 kPa)

Pression de fonctionnement minimale

 4 lb/po² (27.5

 kPa)

Température maximale de l'air 

ambiant

50

 

°C  (122

 

°F) 

Température minimale de l'air 

ambiant

0

 

°C  (32

 

°F) 

Humidité maximale

100 %

Dureté maximale

120 ppm 

(7 grains par gallon)

Taux maximal de fer

0,3 ppm

Taux minimal de transmission UV

75 %

   Installation

À la verticale ou à 

l'horizontale*

Durée de vie nominale de la lampe

1 an

Certification

Généralit

és (t

ous modèles)

4

OPERA

TION

FUNCTIONNEMENT

Débits

Débit maximal pour une 

dose de 16 mj/cm

2

à un TUV de 70 %

______

4,3 gpm

(16,3  lpm)

8,9 gpm

(33,7  lpm)

8,9 gpm

(33,7  lpm)

15,8 gpm

(59,8  lpm)

26,1 gpm

(98,8  lpm)

Débit maximal pour une 

dose de 16 mj/cm

2

à un TUV de 85 %

3 gpm

(11 lpm)

6 gpm

(23 lpm)

16 gpm

(60  lpm)

16 gpm

(60  lpm)

29 gpm

(110  lpm)

45 gpm

(170  lpm)

Débit maximal pour une 

dose de 30 mj/cm

2

à un TUV de 85 %

1 gpm

(4 lpm)

4 gpm

(15  lpm)

9 gpm

(34  lpm)

9 gpm

(34  lpm)

15 gpm

(57  lpm)

25 gpm

(95  lpm)

Débit maximal pour une 

dose de 40 mj/cm

2

à un TUV de 85 %

1 gpm

(4 lpm)

3 gpm

(11  lpm)

7 gpm

(26  lpm)

7 gpm

(26  lpm)

12 gpm

(45  lpm)

20 gpm

(76  lpm)

T ension

Électrique

120 V ou 240

 V (CA)

de 100 à

 240

 V 

(CA)

de 100 à

 240

 V 

(CA)

de 100 à

 240

 V 

(CA)

de 100 à

 240

 V 

(CA)

de 100 à

 240

 V (CA)

Fréquence

de 50 à

 60

 Hz

de 50 à

 60

 Hz

de 50 à

 60

 Hz

de 50 à

 60

 Hz

de 50 à

 60

 Hz

de 50 à

 60

 Hz

Courant max.

0,3 A

 0,4 A

0,5 A

0,5 A

0,85 A

1,2 A

Consommation 

électrique maximale

22 W

36 W

50 W

50 W

83 W

130 W

Puissance de la lampe

14 W

25 W

40 W

40 W

70 W

110 W

Autr

e

Matière composant la 

chambre à eau

304 AC. INOX.

304 AC. INOX.

304 AC. INOX.

304 AC. INOX.

316 AC. INOX.

316 AC. INOX.

Entrée/sortie

3/8 po FNPT

3/4" po NPT

3/4 po NPT

3/4 po NPT

1 po NPT

1 po NPT

A

B4*

C4*

E4/E4 Plus*

F4/F4 Plus*

D4/D4 Plus*

Operating P

aramet

ers

Pression de 

fonctionnement maximale

125 lb/po² (862

 kPa)

Pression de fonctionnement minimale

 4 lb/po² (27.5

 kPa)

Température maximale de l'air 

ambiant

50

 

°C  (122

 

°F) 

Température minimale de l'air 

ambiant

0

 

°C  (32

 

°F) 

Humidité maximale

100 %

Dureté maximale

120 ppm 

(7 grains par gallon)

Taux maximal de fer

0,3 ppm

Taux minimal de transmission UV

75 %

   Installation

À la verticale ou à 

l'horizontale*

Réducteur de débit

Oui

Homologation NSF

NSF Standard

 55

 

Class B

Durée de vie nominale de la lampe

1 an

Autres homologations

Modèles homologués 

NSF 55 

classe B 

(-V)

* L

es systèmes

 à 

capteurs 

doivent

 être

 montés

 à 

la ver

ticale. 

** L

e modèle

 A

 est

 le

 seul

 système

 à 

être homologué

 par

 CS

A mais

 non

 par

 UL.

* NSF Standard 55 Class B certified and non-certified

*Modèles respectant les exigences de la classe B de la norme NSF 55 et modèles non homologués

4

Содержание TrojanUVMax A

Страница 1: ...st advanced UV technology available today your UV system is designed to provide you with years of trouble free operation with minimal maintenance required 425 Clair Rd W Guelph Ontario Canada N1L 1R1...

Страница 2: ......

Страница 3: ...he UV system unless they have been given supervision or instruction 15 SAVETHESE INSTRUCTIONS SAFETY INSTRUCTIONS GROUNDING This product must be grounded If it should malfunction or breakdown groundin...

Страница 4: ...ions 4 Components 5 Dimensions and layout 7 Installation 9 Installing the UV system 9 Disinfecting the water lines 11 Operation 14 Control panel not applicable to Model A 14 Troubleshooting 15 Low UV...

Страница 5: ...001 PART B REPLACEMENT LAMP C LAMPE DE RECHANGE C DATE OF MANUFACTURE MODEL A DATE OF MANUFACTURE SERIAL 00000 PART B UV STERILIZER 98HA MODEL A 7 24084 XXXXX MODEL A SERIAL NUMBER 000001 IS AN EXAMPL...

Страница 6: ...4 SST 304 SST 304 SST 316 SST 316 SST Inlet Outlet 3 8 FNPT 3 4 NPT 3 4 NPT 3 4 NPT 1 NPT 1 NPT A B4 C4 E4 E4 Plus F4 F4 Plus D4 D4 Plus Operating Parameters Maximum operating pressure 125 PSI 862 kPa...

Страница 7: ...pply includes Power supply mounting bracket Reference card Safety cap Lamp cord B4 C4 D4 D4 Plus E4 E4 Plus F4 F4 Plus 650713 005 650713 006 650713 007 650713 008 650713 001 650713 002 650713 003 6507...

Страница 8: ...All except Model A Chamber clamp s All Solenoid valve kit optional includes Junction Box D4 D4 Plus 3 4 E4 E4 Plus F4 F4 Plus 1 650717 001 650717 002 CoolTouch valve optional D4 Plus 3 4 E4 Plus F4 Pl...

Страница 9: ...3cm 5 5 14cm 2 5 6 5cm 48 122cm B4 14 5 37cm 4 10cm 72 183cm 8 5 22cm 6 15cm 54 137cm C4 20 5 52cm 4 10cm 72 183cm 8 5 22cm 6 15cm 54 137cm D4 D4 Plus 20 5 52 cm 4 10cm 72 183cm 8 5 22cm 6 15cm 54 137...

Страница 10: ...during periods of no flow Flow Restrictor Restricts water from flowing over the maximum NSF certified flow rate ensuring an adequate UV dose is maintained Sample valve Allows for sampling of water im...

Страница 11: ...2 10 5 6 7 8 9 Install power supply mounting bracket to wall using four 8 screws not provided Make all necessary plumbing connections referring to Dimensions and Layout drawing Model A Skip to step 9...

Страница 12: ...he outlet and check for leaks Proceed to DisinfectingThe Water Lines Push safety cap into place Ground lug Locking screw Ground and strain relief wires 16 Outlet must be protected by a Ground Fault Ci...

Страница 13: ...water lines is therefore required after initial system installation and following any period of time during which the system is inoperative whether due to an alarm condition a power failure or for an...

Страница 14: ...stop the flow Allow hot water if present to flow until you can smell bleach then stop the flow Repeat procedure at all water outlets Remember to include all faucets washing machines toilets outside t...

Страница 15: ...VERVIEW MAINTENANCE OPERATION 21 18 Flush all water outlets until bleach can no longer be smelled at least 5 minutes 20 23 24 19 Remainder of steps for Plus models only 22 Plug sensor into blue jack 1...

Страница 16: ...active due to lamp failure Yellow Flashing red Solid red Green Indicator lights only indicate a problem with the component when flashing red 1 2 3 Lamp timer display Counts down from 365 days to show...

Страница 17: ...nough Control humidity or relocate unit Inspect and replace if deteriorated Tighten assembly hand tight Leak detected at sensor if so equipped UV sensor o rings are damaged deteriorated or incorrectly...

Страница 18: ...sensor and hold until the audible alarm stops usually about 5 seconds If the audible alarm is still present after 30 seconds release the button and replace the sensor 3 Refer to Sleeve Cleaning And L...

Страница 19: ...lamp Lamp replacement The amount of UV light created by the lamp decreases over time requiring that the lamp be replaced every 12 months NOTE The UV system is designed to operate continuously and shou...

Страница 20: ...y Strain relief wires should remain connected Model A Squeeze sides opposite of tabs Squeeze tabs 1 2 1 2 Model A Safety cap lamp plug and power supply figures will look slightly different than those...

Страница 21: ...e bolt with 2 new o rings Screw lamp into sleeve hand tight Caution Over tightening will break the sleeve 1 2 1 2 Lamp tab Sleeve bolt 2 1 Make sure lamp sleeve assembly is centered Caution Over tight...

Страница 22: ...ring clamp if equipped to push lamp plug onto end of lamp ring clamp 24 25 22 Disinfect the water lines Refer to Disinfecting the Water Lines in Installation section If lamp was replaced and you have...

Страница 23: ...d Hardware Components VIQUA warrants the electrical power supply and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase Dur...

Страница 24: ...603037_Rev_H Printed in Canada Copyright 2011 VIQUA aTrojanTechnologies Company Guelph Ontario Canada...

Отзывы: