The light will display this color pattern for five seconds after the button is pressed, and whenever the condition
changes during use.
When the battery is charging, the light will indicate the state of charge with a color pattern. If the indicator light is off
while charging the battery then it is not charging or it is almost fully charged.
4.13 CAN BUS
The Trillium Group 24 battery is equipped with a CAN bus interface to allow communication with other CAN-based
devices. The battery side connector information is as follows:
QUANTITY
PART DESIGNATION
MANUFACTURER
DTM AWG 20 Solid Pin
3
0460-202-20141
Deutsch
DTM Receptacle
1
DTM04-3P
Deutsch
The user is responsible for selection and procurement of mating hardware and cabling, including the specified
120 Ω termination between the CAN-H and CAN-L wires at each end of the CAN cable. Details on the functionality
of the CAN bus are contained in the document entitled, “Trillium Gen 1 - CAN Basic Protocol”, available at
https://www.trojanbattery.com/literature.
If required, technical support is available as outlined at the front of this manual.
4.14 PROHIBITION AGAINST UNBALANCED LOADS
All loads in Trillium systems composed of multiple batteries in series must be connected to the entire string.
Connection of any loads to a sub-string, no matter how small, will disrupt battery-to-battery balance and cause
significant loss of system capacity, extended charge times, and/or total system shutdown.
For instance, in a system composed of four TR 12.8-92 batteries in series operating at a nominal voltage of 51.2V,
all loads must be connected between the positive post of the most positive battery and the negative post of the most
negative battery and designed to operate at that voltage. It would not be acceptable to drive a separate 12V load from
just one of the batteries.
BATTERY LEVEL
INDICATOR
PRESS
BATTERY
STATUS
100%
0%
20%
50%
SOLID LIGHT
BLINKING LIGHT
LIGHT COLOR PATTERN BATTERY CONDITION
Solid Green
90% - 100% Capacity Remaining
Blinking Green
50% - 90% Capacity Remaining
Solid Yellow
35% - 50% Capacity Remaining
Blinking Yellow
20% - 35% Capacity Remaining
Solid Red
10% - 20% Capacity Remaining
Blinking Red
0% - 10% Capacity Remaining
Blinking Green and Red
Battery is shut off