Troglotech T804 User Manual SD VERSION Page 19
MAINTAINANCE—T804 SYSTEM
When the Rod is returned to the coiler ensure that most debris is removed, although
the T804 is fully sealed to IP 67 the use of Jet Washers is strictly prohibited as the
pressure can exceed acceptable limits. Keeping the Rod clean as it is returned to the
coiler is the preferable method of keeping the T804 in good condition.
After each week’s operation ensure that the Rod Guide is clear of debris, clean if nec-
essary using warm water and a paintbrush to get into the inaccessible parts. Wipe
down the enclosures with warm water and a mild detergent using a cloth. Perform
cleaning operations with camera and accessories connected.
MAINTAINANCE—–T800 CAMERA
It is best practice to leave the camera and skids fitted to the T804 system. If you need
to remove the camera ensure that the Termination is clean before removal. When
replacing the camera ensure that the threads are clean and that the ‘O’ rings are well
lubricated with Silicone Grease. Never use solvents (such as Ambersil) to clean the
termination as this will damage the o-rings. Keep the windows clean with a damp
cloth and a small brush to remove debris from the front guard.
The Lens Window is the only user-replaceable part on the T800 camera, although the
surface is extremely hard it may become scratched over a period of time and this will
affect the picture quality. The replacement requires the purchase of a Lens Window
Kit which includes the Quartz window and the sealing ‘O’ ring. Before attempting the
replacement ensure that the camera is perfectly clean and there is no debris in the
window aperture. Please see the T800 User Manual for lens window replacement.
MAINTAINANCE—–T812 CAMERA
It is best practice to leave the camera and skids fitted to the T804 system. If you need
to remove the camera ensure that the Termination is clean before removal. When
replacing the camera ensure that the threads are clean and that the ‘O’ rings are well
lubricated with Silicone Grease. Never use solvents (such as Ambersil) to clean the
termination as this will damage the o-rings. Keep the windows clean with a damp
cloth (microfiber cloths are best for this practice).
REPAIRS/SERVICING
The T804 has no user serviceable parts. Please refer to your Distributor for repairs
and service.
MAINTAINANCE