AWC708C PLUS Motion Control User Manual
WWW.SZTROCEN.COM
90
the panel. When set incorrectly, the axis moves opposite
direction.
Limit Polarity
The control level that limit switch passes to the control
panel. When set incorrectly, the limit will fail.
If the limit sensor is NPN, the limit polarity is negative.
If the limit sensor is PNP, the limit polarity is positive.
Range(mm)
The working range of machine.
Start Speed
(mm/s)
The initial speed at which the axis moves from rest to
motion.
Max ACC
(mm/s2)
The maximum acceleration value of the motion axis when
the axis increases or decreases speed.
Max Speed (mm/s)
The maximum speed which the motion axis supports.
Zero Offset (mm)
The zero point of machine will move a zero offset distance
along X+ direction.
In some special cases, the machine's origin point cannot be cut. AWC708C
PLUS supports the Zero Offset function, which can move the zero point of
machine to other positions along the positive direction of the motion axis.
Take X axis as example, if the X axis
【
Zero Offset
】
is set to 50mm, the
machine origin point will move 50mm along X+ direction, and this position
is the new origin (zero) point of machine.
7.2 Laser Parameters
On the
Manufacture Params Settings
page, move cursor to
【
Laser
Parameters
】
and press
【
Enter
】