Triumph Tiger Explorer Скачать руководство пользователя страница 5

5 of 8

Installation of the Alarm Unit

1.

Remove the left and right hand fuel tank infill panels.
Refer to the service manual.

2.

Remove the four fixings and then remove the seat
bridge.

1. Seat bridge
2. Fixings

3.

Locate the black, twelve-pin connector on the main
wiring harness and remove the connector shorting
plug.

1. Black, twelve-pin alarm connector
2. Shorting plug

Note:

The alarm connector is an unused black coloured
terminal block and is located on the frame
beneath the seat bridge of the motorcycle. The
shorting plug is the cover for this terminal block
which is fitted with a double hoop of black cable.

The shorting plug must be returned to
DATATOOL along with the registration
documentation.

1. Alarm/immobiliser connector
2. Shorting plug

Note:

Read the warning notices printed on the cleaning
wipe packet in the fitting kit.

The surfaces to which the alarm unit adhesive
pads are affixed must be clean and dry to ensure
that the adhesive has a sound base to adhere to.
Use the cleaning wipe supplied for this purpose.

2

1

4

2

1

Caution

When fitting self-adhesive parts care must be taken to
ensure positioning is correct and accurate. Once the
adhesive has been attached to the mounting surface, there
is no satisfactory method of removal and re-positioning if
incorrectly aligned. Initial bonding is instant, full bonding is
achieved after 72 hours.

cckk

1

2

Содержание Tiger Explorer

Страница 1: ...and performance Completely read all of these instructions before commencing the installation of the accessory kit in order to become thoroughly familiar with the kit s features and the installation p...

Страница 2: ...pproved parts accessories and conversions fitted by a trained technician of an authorised Triumph dealer The fitment of parts accessories and conversions by a technician who is not of an authorised Tr...

Страница 3: ...eaning wipe supplied for this purpose 8 Peel off the backing strip from the adhesive pad on the reed switch magnet 9 Align the reed switch magnet to the fixing holes on the underside of the seat Apply...

Страница 4: ...y following the routing of the rear light harness Secure the wiring to the rear light harness clip and using the cable ties provided secure it in two positions Ensure the wiring is not located such th...

Страница 5: ...a double hoop of black cable The shorting plug must be returned to DATATOOL along with the registration documentation 1 Alarm immobiliser connector 2 Shorting plug Note Read the warning notices printe...

Страница 6: ...rap from the kit as shown below 1 Alarm unit 2 Seat bridge 3 Strap 6 Slide the heat shrink over the alarm immobiliser harness 7 Connect the alarm immobiliser wiring to the main wiring harness connecto...

Страница 7: ...ive red lead first 16 Refit the pillion seat only 17 Check all functions of the alarm as detailed in the user guide Note When satisfied that the alarm is functioning correctly the connection between t...

Страница 8: ...number varies from Triumph model to model dependent upon the fitting kit used Write the relevant MIRRC evaluation number as indicated below onto the certificate of installation next to the alarm seria...

Отзывы: