YEARLY MAINTENANCE
Grease rub blocks and column surface contacting rub blocks with dry or Teflon based lube (Spray Lube)
Change the hydraulic fluid. Good maintenance procedure makes it mandatory to keep hydraulic fluid clean. No
hard fast rules can be established;-operating temperature, type of service, contamination levels, filtration, and
chemical composition of fluid should be considered. If operating in dusty environment shorter interval may be
required. Fluid Change intervals can vary between 1-5 years depending on conditions.
Only a trained maintenance expert should perform the following items.
Replace hydraulic hoses
Replace chains and rollers.
Replace cables and sheaves.
Replace or rebuild air and hydraulic cylinders as required.
Replace or rebuild pumps / motors as required.
Check hydraulic and air cylinder rod and rod end (threads) for deformation or damage.
Check cylinder mount for looseness and damage.
Relocating or changing components may cause problems. Each component in the system
must be compatible; an undersized or restricted line will cause a drop in pressure. All valve,
pump, and hose connections should be sealed and / or capped until just prior to use. Air hoses
can be used to clean fittings and other components. However, the air supply must be filtered
and dry to prevent contamination. Contamination is the most frequent cause of malfunction or
hydraulic equipment.