T70Z

electric shower

INSTALLATION AND OPERATING INSTRUCTIONS 

Please read this book thoroughly and familiarise yourself with all instructions before commencing 

installation and keep it for future reference. 
The shower installation 

MUST

 be carried out by a suitably qualified person, 

in the sequence of  

this instruction book. 

IMPORTANT SAFETY ADVICE

The shower unit 

MUST BE

 switched off at the 

isolating switch when not in use. This is a  

safety procedure recommended for all 

electrical appliances.
The shower head and hose supplied with this 

product are a safety critical part of your shower. 

Failure to use genuine Triton parts may cause 

injury and invalidate your guarantee.

FOR YOUR SERVICE REFERENCE

NOTE DOWN THE PRODUCT CODE BELOW

(FROM THE FRONT OR TOP OF THE BOX)

ALTERNATIVELY REGISTER BY TEL: 024 7637 8321

THIS OFFER IS NOT VALID OUTSIDE THE UK

REGISTER ONLINE

ENTER A PRIZE DRAW

WIN

£100

LOVE2SHOP VOUCHERS

VISIT OUR WEBSITE TODAY

TRITONSHOWERS.CO.UK/REGISTER

PRODUCT REGISTRATION IS ONLY AVAILABLE

TO UNITS PURCHASED & INSTALLED IN THE UK

Содержание T70Z

Страница 1: ...hen not in use This is a safety procedure recommended for all electrical appliances The shower head and hose supplied with this product are a safety critical part of your shower Failure to use genuine...

Страница 2: ...s appliance is intended to be permanently connected to the water mains and not connected by a hose set A suitable double pole isolation switch for supply disconnections must be incorporated in the fix...

Страница 3: ...ust comply with Water Regulations Building Regulations or any particular regulations as specified by Local Water Company or Water Undertakers and should be in accordance with BS EN 806 2 2 The supply...

Страница 4: ...ler than in the summer so the flow rate will vary between seasons at any one temperature setting At different times of the year you may have to adjust the position of the temperature control to mainta...

Страница 5: ...quirements 9 Siting of the shower 10 PRD Pressure Relief Device 10 Fitting the shower to the wall 11 13 Pipe access points front cover 12 Plumbing connections 14 Electrical connections 15 Replacing th...

Страница 6: ...100mm 300mm ENTRY POINTS DIMENSIONS WATER Left Bottom Back Top Right Bottom Back CABLE Left Bottom Back Top Right Bottom Back Top Z uni fit kit required Back Back Others Others Inlet connection 15mm d...

Страница 7: ...he whole installation at the mains supply and remove the correct fuse 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a ring main spur socket outle...

Страница 8: ...g in a bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Where shower cubicles are located in any rooms other than bathrooms all socket outlets in those roo...

Страница 9: ...hower for full performance for 7 5Kw 8 5Kw Maximum static pressure 1000 kPa 10 bar Maximum inlet temperature 28 C Minimum inlet temperature 2 C Fig 5 shows a typical system layout Do not use jointing...

Страница 10: ...ead be constrained by a fixed or sliding attachment so that it can only discharge water at a point not less than 25mm above the spill over level of the relevant bath shower tray or other fixed applian...

Страница 11: ...ntegral part of the cover DO NOT attempt to remove them Lift the cover from the backplate Entry points can be found on page 6 The water inlet fig 7 has been designed to allow left or right fitting To...

Страница 12: ...op entry has been chosen remove the appropriate pipe cover If bottom entry has been chosen carefully remove the appropriate cut out using a junior hacksaw Please note The bottom cut outs are not desig...

Страница 13: ...e location of the fixing holes in the backplate are shown in fig 10 Drill and plug the wall An appropriate drill bit should be used If the wall is brick plasterboard or a soft building block appropria...

Страница 14: ...r IMPORTANT Before completing the connection of the water supply to the inlet of the shower flush out the pipework to remove all swarf and system debris This can be achieved by connecting a hose to th...

Страница 15: ...cable must be stripped back to the minimum The supply cable must be secured either by routing through conduit or in trunking or by embedding in the wall in accordance with current IEE regulations The...

Страница 16: ...wise until the flat section is at the bottom fig 13 2 With the cover off the shower turn the stabiliser valve spindle fully clockwise until resistance is felt fig 14 4 With the cover off the shower tu...

Страница 17: ...control to MINIMUM FLOW may cause the PRD to operate 2 Turn on the electric and mains water supplies to the shower 3 Turn the power selector to the COLD setting fig 18 and wait until water starts to...

Страница 18: ...he shower head it will not alter the water temperature The RED symbol is an economy setting for using less energy when the ambient mains water temperature is high during warmer months Temperature adju...

Страница 19: ...advisable to be certain that the showering temperature is satisfactory by testing with your hand before stepping under the shower head There will always be a time delay of a few seconds between select...

Страница 20: ...the device will disconnect the heating elements It will require a visit from a qualified engineer to determine the nature of the fault and replace the safety device once the unit has been repaired Tw...

Страница 21: ...lectricity supply and water supply at the mains The inlet filter is situated in the bottom of the inlet pipe fig 20 To gain access to the filter remove the cover and then unscrew the assembly from the...

Страница 22: ...flow rate via temperature control Is water supply mains or tank fed If tank fed replumb to mains water supply or see 4 2 4 If mains fed make sure that the mains stopvalve is fully open and there are n...

Страница 23: ...4 3 1 4 3 2 4 4 1 5 1 1 6 1 1 6 2 1 6 3 1 6 4 1 7 1 1 7 2 1 7 3 1 required see rating label Reduction in ambient water temperature Electrical malfunction or safety cut out operated Water pressure has...

Страница 24: ...e DTS registration number DTS 501317 1 All our electric products are labelled accordingly with the crossed out wheeled bin symbol This indicates for disposal purposes at end of life that these product...

Страница 25: ...2 HEATER ELEMENTS USED HEATER ELEMENTS USED NONE OF THE ELEMENTS USED 0 1 2 1 OF THE ELEMENTS USED HEATER ELEMENTS USED 2 OF THE ELEMENTS USED 0 1 2 H O T HOT COLD Power Knob settings Temperature Kno...

Страница 26: ...T70Z electric shower 26...

Страница 27: ...T70Z electric shower 27...

Страница 28: ...xpress or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton...

Отзывы: