REPLACING THE COVER
The power selector spindle must be aligned as
shown
(fig.14)
.
To ensure that the temperature control is correctly
positioned on the stabilising valve, temporarily
place the cover in position so that the splines
engage and rotate the temperature control fully
anti-clockwise.
Remove the cover and position the temperature
control knob so that it points towards the No.1
position
(fig.15)
.
Position the power selector to the 'STOP' position
(fig.16)
.
Replace the cover squarely to the backplate and
guide into position so that the knobs locate
correctly into the splined spindles. Should any
difficulty arise, re-check the points above.
Secure the cover in position with the three
retaining screws.