Forte
µ3RZHU2Q¶
LQGLFDWRU
OpeRaTING FUNCTIONS
power on indicator
(fig.)
When the electricity supply to the shower is
switched on at the isolating switch, the ‘Power
On’ indicator will light.
Note:
Should the safety cut-out device operate,
the indicator will remain lit.
Low water pressure cut-out
If the water pressure falls below the minimum
required for correct operation of the shower,
power will be switched off to the heating
elements preventing any maintained
temperature rises (water will continue to flow).
Power will automatically be restored when
adequate water pressure returns.
Temperature limiter
During normal operation if an overheat
temperature is sensed, power to the elements
will be reduced. Water will continue to flow.
When the temperature has cooled sufficiently,
power to the elements will be automatically
restored to the previous setting at the time of
interruption.
Safety cut-out
The unit is fitted with a non-resettable
thermal cut-out safety device. In the event of
abnormal operation which could cause unsafe
temperatures within the unit, the device will
disconnect the heating elements. It will require a
visit from a qualified engineer to determine the
nature of the fault and replace the safety device,
once the unit has been repaired.
NoTE:
In normal use, it is in order to leave the
water supply permanently on to the shower
unit, but as with most electrical appliances,
the unit must be switched off at the
isolating switch when not in use.