Exe Inclusive Bar Mixer Shower

1

Fig.1

A.

  Thermostatic bar mixer valve

B.

  Dogleg connector X2

C.

  Cover trim X2

B

MAIN COMPONENTS

C

C

A

Содержание EXE LEVER

Страница 1: ...BY TEL 024 7637 8321 INSTALLATION AND OPERATING INSTRUCTIONS Please read this book thoroughly and familiarise yourself with all instructions before commencing installation and keep it for future refer...

Страница 2: ...ADJUSTMENT RANGE 11 ADJUSTING THE MAXIMUM TEMPERATURE SETTING 11 OPERATING THE SHOWER 12 DIMENSIONS 13 APPROVALS 14 TMV2 REQUIREMENTS 12 MONTH VERIFICATION 14 PRODUCT FLOW RATES 14 MAINTENANCE 15 FAUL...

Страница 3: ...Exe Inclusive Bar Mixer Shower 1 Fig 1 A Thermostatic bar mixer valve B Dogleg connector X2 C Cover trim X2 B MAIN COMPONENTS C C A...

Страница 4: ...t the mixer shower Water Minimum Flow Rate For best performance within the specified running pressure range a minimum flow of 8 litres per minute should be available to both inlets Water Temperature R...

Страница 5: ...ugh before fitting Commercial Applications It is recommended that for all commercial applications easily accessible in line filters are used to aid maintenance Hard Water Areas a If it is intended to...

Страница 6: ...boost pressures as shown please refer to the pump installation guide to establish the minimum head requirements for automatic operation of the pump Hot water cylinder Cold supply Hot supply Alternativ...

Страница 7: ...or systems with no cold water take off after the appliance reducing valve it will be necessary to fit an additional drop tight pressure reducing valve when the mains pressure is over 5 bar The drop ti...

Страница 8: ...ar running An expansion vessel MUST be fitted and regularly maintained to ensure the unit is not damaged by excess pressures This may already be installed externally or internally within the thermal s...

Страница 9: ...shower area having decided on the position of the shower and direction of pipe entry for example rising falling or rear entry The hot and cold water pipes should be securely attached within the wall...

Страница 10: ...ood the wall and complete the tiling NOTE It is advised to use a suitable sealer around the variable connector where it enters the wall to stop water ingress fig 9 Screw the supplied cover trims onto...

Страница 11: ...clockwise until it stops NOTE The flow control graphic styles of this may vary should be positioned so that the front edge of it is at the 12 o clock position The remainder of the graphic should run t...

Страница 12: ...in the requirements as stated on page 2 Make sure the temperature control right hand side is at the maximum temperature setting WITHOUT operating the maximum temperature override button Allow the show...

Страница 13: ...temperatures must never exceed 46 C at terminal fitting The British Burns Association recommends 37 to 37 5 C as a comfortable bathing temperature for children In premises covered by the Care Standar...

Страница 14: ...ops flowing fig 15 To adjust the water temperature rotate the temperature control right hand side clockwise for a cooler shower or anti clockwise for a hotter shower fig 16 To overcome the maximum tem...

Страница 15: ...Exe Inclusive Bar Mixer Shower 13 290 00 1 2 BSP 180 00 150 00 3 4 BSP 4 0 5 0 56 25 DIMENSIONS All dimensions regarding the product and installation are approximate...

Страница 16: ...ing then the valve is working correctly and no further service work is required If there is a residual flow during the commissioning or the annual check this is acceptable providing the temperature of...

Страница 17: ...a Initially check the filters for debris once every three months and clean if necessary b Perform a thermal shut off test every three months and check the maximum temperature setting See the Commissi...

Страница 18: ...supply blocked or restricted 2 6 Flow regulator not fitted HP systems only 3 1 Flow regulators not fitted 1 1 1 Refer to the Commissioning section 1 2 1 Reposition temperature control knob 1 3 1 Repo...

Страница 19: ...t the inlet filters Clean if necessary 4 3 1 Turn off the shower and consult a suitably competent plumber 4 4 1 Clean shower head 4 5 1 Reduce the simultaneous demand 4 5 2 Make sure stop service valv...

Страница 20: ...ent of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information cont...