Aspirante thermostatic power shower
23
FAULT FINDING (continued)
Symptom Cause
Action/Cure
It is advised all electrical maintenance/repairs to the shower
should be carried out by a suitably qualified person.
In the unlikely event of a fault occurring please
contact Triton Customer Service. Do not remove
the shower from the installation.
4
Water does
not flow or is
reduced.
5
Cross flow of
hot and cold
water into
system.
6
Water
dripping from
showerhead
when turned
off.
4.1
Water supplies cut off.
4.2
Shower blocked or air
in the system.
4.3
Showerhead blocked.
4.4
Blocked filters.
5.1
Dirt/debris in check
valves.
6.1
Debris in solenoid
valve.
6.2
Potentiometer faulty.
4.1.1
Check water elsewhere in house and
if necessary contact the local Water
Company.
4.2.1
Switch off shower and contact Customer
Service.
4.3.1
Clean showerhead.
4.4.1
Clean filters.
5.1.1
Isolate water to unit. Remove check valves.
Clean and replace.
6.1.1
Call Customer Service.
6.2.1
Call Customer Service.