background image

7

ARGO G60 I

NSTALLATION

 M

ANUAL

1

Top Function 

Key

46 15/16”

[1193mm]

2

#5 Key

(Main Keypad)

36 1/2”

[928mm]

3

Card Reader

39 1/16”

[992mm]

4 Receipt Printer

38 1/4”

[972mm]

5

Bill Tray

27 3/16”

[690mm]

Feature

Height

Customer Access Dimensions

C

ABINET

 F

RONT

 V

IEW

C

ABINET

 S

ERVICE

 A

REA

 D

IMENSIONS

Dimension

Preferred Area

Minimum Area

A

26” [660]

24 1/2” [622]

B

33 9/16” [853]

31 1/2” [799]

C

21 3/8” [542]

21 15/16” [558]

D

12 3/4” [324]

10 5/8” [269]

Dimensions

Shown in inches/millimeters

i

i

2” [51] clearance around 

cabinet sides and rear

Содержание ARGO G60

Страница 1: ...B STREET LONG BEACH MS 39560 PHONE 800 259 6672 FAX 228 868 9445 2014 Triton All Rights Reserved TRITON logo is a registered trademark of Triton Systems of Delaware LLC TDN 07103 00053 AUTOMATED TELLE...

Страница 2: ...ism into the unit until the unit is bolted down to the ground If the mechanism is installed prior to bolting the unit down the unit could tip over and personal injury could occur Follow the installati...

Страница 3: ...UNITS 12 CABINET INSTALLATION 13 UNPACK ATM 14 MARK DRILL MOUNTING HOLES 15 INSTALL STANDARD ANCHORS BOLT ATM TO FLOOR 16 ROUTE AC POWER AND COMMUNICATION CABLE 17 APPENDIX A SOFTWARE LICENSE AGREEMEN...

Страница 4: ...unit are met 9 Install the unit at a height which meets the ADA DDA CSA accessibility regulations for the state country installed Refer to Appendix B TOOLS REQUIRED Torque wrench adjustable to at leas...

Страница 5: ...Plan operator training exercises optional 10 Install communication lines and test 11 Ensure installation accessories are available TEMPERATURE HUMIDITY 1 The ATM will operate over a range of temperat...

Страница 6: ...ax machines Point of Sale devices Proximity to Interference Sources The telephone line must not be in close proximity to noisy devices that could induce interference into the ATM communications channe...

Страница 7: ...4 972mm 5 Bill Tray 27 3 16 690mm Feature Height Customer Access Dimensions CABINET FRONT VIEW CABINET SERVICE AREA DIMENSIONS Dimension Preferred Area Minimum Area A 26 660 24 1 2 622 B 33 9 16 853...

Страница 8: ...8 ARGO G60 INSTALLATION MANUAL CABINET DIMENSIONS SIDE VIEWS Left Left Right Right...

Страница 9: ...9 ARGO G60 INSTALLATION MANUAL CABINET TOPPER CABINET SIGN AREA BACKLIT GRAPHIC Rear Side Front...

Страница 10: ...10 ARGO G60 INSTALLATION MANUAL CABINET FOOTPRINT...

Страница 11: ...11 ARGO G60 INSTALLATION MANUAL CABINET DECAL AREA SUGGESTED DECAL AREA VISIBLE DECAL AREA...

Страница 12: ...hen replacing older TritonATMs with theARGO G60 you may be able to use holes already drilled to install the ATM See the table below for corresponding hole sites CABINET ARGO G60 9100 with SDD deep ver...

Страница 13: ...RGO G60 ATM is designed for INDOOR use only WARNING DO NOT APPLY POWER TO THIS TERMINAL UNTIL THE INSTALLA TION IS COMPLETE WARNING Do NOT install the mechanism into the unit until the unit is bolted...

Страница 14: ...accessory box is shipped inside the cabinet enclosure Open and inspect the contents Check the contents against the enclosed packing list and report any missing parts to Triton 11 Unbolt the ATM from t...

Страница 15: ...s will help guide the masonry bit that will be used to drill the anchor bolt holes in the next step Mark Drill Mounting Holes 5 Use a portable vacuum cleaner to remove any dust or debris that may have...

Страница 16: ...ting by aligning the base over the four holes drilled in the previous procedure 3 Place an anchor bolt through the cabinet base and into one of the mounting holes Use a ball peen hammer to tap the bol...

Страница 17: ...tighten down firmly Use anchor bolt in each mounting hole Hammer bolts snuggly into drilled holes NOTE Before you start unlock and open the control panel Verify that the power switch on the unit s pow...

Страница 18: ...s then use an 11 32 driver to tighten the nuts This unit may be equipped with more than one power cord Disconnect All Power Cords prior to Servicing For continued fault protection follow the correct v...

Страница 19: ...or on one end and molded plug on the other end 3 Certified for country of installation 4 Rated minimum H05VV F with minimum 0 75 mm2 except where specific countries require 1 0 mm2 conductors 5 Maximu...

Страница 20: ...APPENDIX A SOFTWARE LICENSE AGREEMENT COMPLIANCE EMISSION STATEMENTS...

Страница 21: ...icense to use theATM Software but only in connec tion with the operation of thisATM subject to the terms and restrictions set forth in this LicenseAgreement You are not permitted to use theATM Softwar...

Страница 22: ...ATIVEHASBEENADVISEDOFTHEPOSSIBILITYOFSUCHDAMAGES ORFORANY CLAIMBYANYTHIRDPARTY YOURSOLEREMEDYAGAINSTTRITONFORDEFECTIVEPERFORMANCEOFTHEATMSOFTWARE WILLBE LIMITED EXCLUSIVELYTO REPAIR OR REPLACEMENTOFTH...

Страница 23: ...ith the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will...

Страница 24: ...Appendix B ATM Installation for Accessibility...

Страница 25: ...specified clear floor or ground space shall be positioned for either forward or parallel approach to an element 305 6 Approach One full unobstructed side of the clear floor or ground space shall adjoi...

Страница 26: ...aximum Where the reach depth exceeds 20 inches 510 mm the high forward reach shall be 44 inches 1120 mm maximum and the reach depth shall be 25 inches 635 mm maximum Figure 308 2 2 Obstructed High For...

Страница 27: ...ed States may also have accessibility codes These codes may be more restrictive than the federal guidelines Please verify this with the state where the ATM is to be installed prior to installation For...

Страница 28: ...1180 24 610 46 1170 3 Forward and Parallel Approach If both a forward and parallel approach are possible operable parts of controls shall be placed within at least one of the reach ranges in paragrap...

Страница 29: ...ar floor or ground space for a wheelchair shall adjoin or overlap an accessible route or adjoin another wheelchair clear floor space If a clear floor space is located in an alcove or otherwise confine...

Страница 30: ...required Figures 4d Clear Floor Space in Alcoves 4 2 4 3 Surfaces for Wheelchair Spaces Clear floor or ground spaces for wheelchairs shall comply with 4 5 Ground and Floor Surfaces 4 2 5 Forward Reach...

Страница 31: ...no less than 9 inches 230 mm above the floor Fig 6 a and 6 b If the side reach is over an obstruction the reach and clearances shall be as shown in Fig 6 c Figure 6a Parallel approach side reach Figu...

Отзывы: