A
Q U A S E N S A T I O N
A S 2 0 0 0 T / A S 2 0 0 0
19
ADJUSTING THE MAXIMUM TEMPERATURE
STOP
As a safety feature the shower has a built-in
maximum temperature stop to prevent you
accidentally exceeding your highest desired
temperature. This is set in the factory to provide a
maximum temperature based on the hot and cold
water supplies being 65°C and 15°C respectively.
Procedure:
Pull off the temperature control
(fig.49).
Carefully pull off the maximum temperature stop
mechanism.
To increase the temperature stop setting,
reposition the mechanism anti-clockwise within
the arc of the grooves
(fig.50)
.
To decrease the temperature stop setting,
reposition the mechanism clockwise within the arc
of the grooves
(fig.50)
.
Replace the temperature control by push fitting
onto the adaptor shaft, noting that it will only fit
one way.
Important:
Only adjust the maximum
temperature stop when the hot water is at its
usual storage temperature.
WARNING: The AS2000 manual shower does
not contain a thermostatic valve – it will not
shut off in the event of failure of either the
hot or cold water supplies.
Fig.49
Increase stop position
Maximum
temperature
stop
Decrease stop position
Fig.50