Triton AMORE Скачать руководство пользователя страница 23

23

CLEANING THE FILTER

It is recommended that the filter is periodically 
cleaned in order to maintain the performance of 
the shower. It is essential that this operation is 
carried out by a competent person.

• 

SWITCH OFF

 the electricity and water supply 

at the mains.

•  The inlet filter is situated inside the water inlet 

fitting 

(fig.24)

.  To gain access to the filter, 

remove the cover and bottom trimplate.

•  Unscrew the filter cap from the bottom    of the 

inlet pipe. 

•  Inspect the ‘O’ ring for damage when the 

filter cap is removed. 

•  When cleaning the filter, 

DO NOT

 use a sharp 

object as it will cause damage. It is preferable 
to use an old toothbrush or similar.

•  To reassemble, follow the procedure in 

reverse.

•  Make sure that the sealing ‘O’ ring is in place.
• 

DO NOT

 over tighten the filter cap on 

reassembly.

Instructions for installers and service engineers only

INSTRUCTIONS FOR INSTALLERS AND SERVICE ENGINEERS ONLY

Instructions for installers and service engineers only

Fig.24

Filter

‘O’ ring

Filter cap

Содержание AMORE

Страница 1: ...user IMPORTANT SAFETY ADVICE The shower unit MUST BE switched off at the isolating switch when not in use This is a safety procedure recommended for all electrical appliances The showerhead and hose s...

Страница 2: ...ing other than those specified This appliance is intended to be permanently connected to the water mains and not connected by a hose set A suitable double pole isolation switch for supply disconnectio...

Страница 3: ...th Water Regulations Building Regulations or any particular regulations as specified by Local Water Company or Water Undertakers and should be in accordance with BS EN 806 2 2 The supply pipe must be...

Страница 4: ...r water first check that the sprayplate in the showerhead has not become blocked DO NOT place items such as soap or shampoo bottles on top of the unit Liquid could seep through the joint between the c...

Страница 5: ...8 ONLY Commission the shower in the way described 9 Familiarise yourself with the user operating instructions 10 1 2 3 4 5 6 7 8 9 10 Tick off as you complete PLEASE USE THE FOLLOWING CHECK LIST TO AI...

Страница 6: ...TRICAL INSTALLATION 14 FIT TO THE WALL CONNECT SHOWER SUPPLIES 14 16 FITTING THE COVER 17 COMMISSIONING PROCEDURE 18 CONNECTING THE PCB CABLE 19 USER OPERATING INSTRUCTIONS FUNCTIONS 20 22 CLEANING TH...

Страница 7: ...kPa 10 bar Maximum inlet temperature 28 C Minimum inlet temperature 5 C Inlet connection 15mm diameter Outlet connection BSP male thread MATERIALS ABS Backplate cover controls showerhead Acetal Sprayp...

Страница 8: ...Fig 1 200mm 94mm 300mm ENTRY POINTS DIMENSIONS WATER Left Top Bottom Back Right Bottom Back CABLE Left Top Bottom back Right None Back Back Others Others PLEASE NOTE Deviation from the approved entry...

Страница 9: ...ubt switch off the whole installation at the mains supply and remove the correct fuse 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a ring main s...

Страница 10: ...ile standing in a bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Where shower cubicles are located in any rooms other than bathrooms all socket outlets i...

Страница 11: ...to achieve your preferred shower temperature Fig 5 shows a typical system layout Refer to fig 6 for the correct siting of the shower Position the unit where it will NOT be in direct contact with water...

Страница 12: ...ocked showerhead This may cause the PRD to operate When commissioning the showerhead must be removed from the flexible hose Failure to follow this procedure may cause the PRD to operate Make sure the...

Страница 13: ...make the nut accessible for future adjustments NOTE An additional stop valve complying with Water Regulations must be fitted in the mains water supply to the shower as an independent means of isolati...

Страница 14: ...entry has not been chosen the trim can be fitted complete Should either top cable or top pipe entry have been chosen individually the trim has been designed to be separated and the appropriate trim s...

Страница 15: ...to terminal marked L Once the cables have been installed the two trimplates will need to be fitted IMPORTANT When connecting the cable fully tighten the terminal block screws and make sure that no ca...

Страница 16: ...lectricity supply until the shower cover has been fitted 7 SECTION SECTION NOTE The elements on UK models are to 240V specification and will give a lower kW rating if the voltage supply is below 240V...

Страница 17: ...orrectly minor adjustment may be necessary to align the control and spindle Should any difficulty arise recheck the points above While applying slight pressure to the front cover secure in position wi...

Страница 18: ...this could make the PRD operate Turn on the water supply to the shower at the isolating stop valve Switch on the electricity supply to the shower at the isolating switch Wait until water starts to flo...

Страница 19: ...d edge which is uppermost when correctly fitted to the socket There is also a key way for ensuring correct location into the socket Guide the cover into position so that the knob spindle locates corre...

Страница 20: ...ouched to change the power setting After a new power selection is made the appropriate icon is illuminated and the screen will display Cold Eco or Max to confirm the selection before reverting to disp...

Страница 21: ...to compensate for seasonal changes in ambient water temperature NOTE The preferred knob position on ECO will give a different temperature to the same position on MAX To decrease the shower temperature...

Страница 22: ...When the Start Stop button is pressed to end showering all heating elements are switched off but water will continue to flow for a few seconds flushing out any remaining hot water The screen will flas...

Страница 23: ...plate Unscrew the filter cap from the bottom of the inlet pipe Inspect the O ring for damage when the filter cap is removed When cleaning the filter DO NOT use a sharp object as it will cause damage I...

Страница 24: ...ly 2 2 1 Check if stop valves are fully open Check if a blockage in the inlet filter 2 3 Increase in ambient water temperature 2 3 1 Readjust flow rate to give increased flow 2 3 2 Select economy powe...

Страница 25: ...1 Thermal safety cut out device has operated Have the unit checked by a suitably qualified engineer or contact Customer Service 4 Pressure relief device has operated water ejected from PRD tube 4 1 B...

Страница 26: ...r electric products are labelled accordingly with the crossed out wheeled bin symbol This indicates for disposal purposes at end of life that these products must be taken to recognised collection poin...

Страница 27: ...o START the shower Press the start stop switch Press Start Stop automatically defaullts to Max Power selection Press Max Power the shower will switch to the Max Power setting Press Economy Power the s...

Страница 28: ...credit debit card excluding American Express or Diners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given dur...

Отзывы: