Triton Blue V 1200 Скачать руководство пользователя страница 5

For safety reasons, please be aware that all modifications on the device are forbidden. 
 
If this device will be operated in any way different to the one described in this manual, the product 
may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to 
short-circuit, burns, electric shock, lamp explosion, crash, etc. 
 

INSTALLATION INSTRUCTIONS 
 

a)

 

Installing or replacing the lamp 

h a higher wattage. They generate higher temperatures than which the device was designed for. 
For the installation, you need one     

                                                         

MSR 1200 SA      GY 22 lamp ;

 

Procedure : 
 

 

 

1) Unscrew the 4 screws marked Y, X, W and Z on the back of the housing, holding the plate where 

the lamp is underneath. 

2) Gently pull the socket holder of the lamp housing in the middle. 
3) Carefully insert the lamp into the socket. Please remember there is only one way to insert the lamp. 

Gently slide the lamp and its lamp holder back into place and fasten the 4 screws. 

4) On the access plate there are 3 small screws marked A, B and C. which are used to adjust the lamp   

holder in the lamp housing. You can adjust the 3 screws to fine-turn the position of the lamp to get   
the maximum light output as shown below.

 

A

B

C

A

B

C

 

Please remember the lamp is not a hot-restrike type, you must wait for approximately 10 
minutes after having turned off the lamp before you can turn it back on again. 

 

CAUTION 

Do not operate this device with open cover 

 

b)

 

Mounting the device 

 -                             GS-SMS-Y1200-V1.0-02NR 

Содержание V 1200

Страница 1: ...PROFESSIONAL MOVING HEAD USER S MANUAL V 1200 KEEP THIS MANUAL FOR FUTURE NEEDS...

Страница 2: ...stall this device Features pan 540 tilt 265 colors color wheel1 with 4 dichroic glass panes 2 correction filter 1 UV filter color wheel2 with 6 dichroic glass panes for a total of 7 colors static gobo...

Страница 3: ...or problems If the device has been exposed to temperature changes due to environmental changes do not switch it on immediately The arising condensation could damage the device Leave the device switche...

Страница 4: ...void brute force when installing or operating the device While choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust The minimum distance betw...

Страница 5: ...the housing holding the plate where the lamp is underneath 2 Gently pull the socket holder of the lamp housing in the middle 3 Carefully insert the lamp into the socket Please remember there is only o...

Страница 6: ...to be approved by a skilled person once a year CAUTION Before taking into operation for the first time the installation has to be approved by an expert Cautions The effect should be installed outside...

Страница 7: ...quick lock fasteners of the first Omega holder into the respective holes on the bottom of the device Tighten the quick lock fasteners fully clockwise Install the second Omega holder Pull the safety ro...

Страница 8: ...reventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor connected between pins 2 and 3 which is then plugged into the output...

Страница 9: ...the data is received the display will show A 001 with the actually set address If there is no data received at the DMX input the display flashes A001 with the actually set address This situation can o...

Страница 10: ...lt Reverse Blackout moving Blackout colors Blackout Gobos ON OFF ON OFF ON OFF ON OFF ON OFF Scan fine select ON OFF Blackout while pan tilt moving or color gobo wheel moving Status choose Addr via DM...

Страница 11: ...ment User mode User A seetings User B settings User C settings User s mode Users Mode Set Preset User mode PAN Save and Active PAN CH NO 01 Please wait Preset User modes Select Programs Program 1 Prog...

Страница 12: ...Gobo 4 shake slow to fast 203 255 Rot gobo wheel cont rotation slow to fast Channel 3 Rotating gobo index rotating gobo rotation 0 127 Gobo indexing 128 187 Forwards gobo rotation from fast to slow 1...

Страница 13: ...cro 1 136 143 Macro 2 144 151 Macro 3 152 159 Macro 4 160 167 Macro 5 168 175 Macro 6 176 183 Macro 7 184 191 Macro 8 192 199 Macro 9 200 207 Macro 10 208 215 Macro 11 216 223 Macro 12 224 231 Macro 1...

Страница 14: ...192 255 Zoom 4 Channel 14 Iris 0 191 Max diameter to Min diameter 192 223 Pulse closing fast to slow 224 255 Pulse opening slow to fast Channel 15 Color Wheel 2 0 13 Open white 14 27 Red 28 41 Light...

Страница 15: ...ixture has more than 3 errors If the fixture has more than 3 errors including 3 errors all the channels can not work properly but if the fixture has less than 3 errors only the channels which have err...

Страница 16: ...ction sensor failed or magnet missing or the stepping motor is defective or its driving IC on the main PCB The Focus is not located in the default position after the reset 13Er Zoom error This message...

Страница 17: ...order genuine parts from your local dealer TECHNICAL SPECIFICATIONS Power supply 208VAC 50Hz 220VAC 50Hz 230VAC 50Hz 240VAC 50Hz 208VAC 60Hz 220VAC 60Hz 230VAC 60Hz 240VAC 60Hz Power consumption max...

Отзывы: