Channel 17 – Lamp on/off, reset, internal programs:
0-19
colour change normal by direction depend on distance
20-39
colour change to any position by direction depend on distance
40-59
Lamp on
60-79
Lamp switch off
80-99
Motor reset
100-119
Internal program 1
120-139
Internal program 2
140-159
Internal program 3
160-179
Internal program 4
180-199
Internal program 5
200-219
Internal program 6
220-239
Internal program 7
240-255
Internal program 8
Channel 18 – Pan fine 16bit
Channel 19 – Tilt fine 16bit
ERROR MESSAGE
When you turn on the fixture, it will make a reset first. The display may show “XXer” while there are problems
with one or more channels. “XX” stands for channel 1,2,3,5,6,7 who has the testing sensor for positioning .
For example, when the display shows “02Er”, it means there is some error in channel 2. If there are some errors on
channel 1, channel 2, channel 5 at the same time, you may see the error message “01Er”, “02Er”,”05Er” flash
repeated for 5 times, and then the fixture will generate a reset signal, all the stepper reset. If the fixture remain error
message after performing reset more than 3 times, it will detect whether the fixture has more than 3 errors. If the
fixture has more than 3 errors (including 3 errors), all the channels can not work properly; but if the fixture has less
than 3 errors, only the channels which have errors can not work properly, others can work as usual.
01Er:
(Color-wheel1 error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the main
PCB). The color wheel is not located in the default position after the reset.
02Er:
(Rotating gobo-wheel error ) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions(sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the main
PCB). The rotating gobo-wheel is not located in the default position after the reset.
03Er
(Rotating gobo indexing error) This message will appear after the reset of the fixture and if the magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the
main PCB). The rotating gobo is not located in the default position after the reset.
04Er
(Static gobo-wheel error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing
-
14
- GS-SMS-Y1200-V1.0-02NR