circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the
main PCB). The Static gobo-wheel error is not located in the default position after the reset.
05Er
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing
circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the
main PCB). The PAN-yoke is not located in the default position after the reset.
06Er:
(TILT-head movement error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the
main PCB). The TILT-head is not located in the default position after the reset.
08Er
(Prism-wheel error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the main
PCB). The Prism-wheel is not located in the default position after the reset.
09Er
(prism indexing error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the main
PCB). The prism indexing is not located in the default position after the reset.
12Er
(Focus error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the main
PCB). The Focus is not located in the default position after the reset.
13Er
(Zoom error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the main
PCB). The Zoom is not located in the default position after the reset.
14Er
(Iris error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the main
PCB). The Iris is not located in the default position after the reset.
15Er
(Color-wheel2 error) This message will appear after the reset of the fixture if the yoke’s magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective ( or its driving IC on the main
PCB). The Color-wheel is not located in the default position after the reset.
CLEANING AND MAINTENANCE
The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly connected and must
not be corroded.
2) There must not be any deformations on the housing, color lenses, fixations and installation spots
(ceiling, suspension, trussing).
1)
Mechanically moved parts must not show any traces of wearing and must not rotate with
unbalances.
2)
The electric power supply cables must not show any damage, material fatigue or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled
installer and any safety problems have to be removed.
-
15
- GS-SMS-Y1200-V1.0-02NR