Control  Quick  Setup

  

For  detailed    instructions    on  display  panel  operations  and  functions  please  adv

ance  to  the  section  titled;;  “Display  Panel  Functions”.  These  

steps  assume  that  you  have  read  and  are  familiar  with  setting  up  a  DMX  serial  data  link.

  

  

DMX

512

  

control  without  “ID”  address

  

The  equipment  operates  on  11  channels  of  DMX  (“STAG”  personality).  A

ddress  each  fixture  in  

increments  of10channels.  (l.e.

1,11,21,31,  

etc...)  To  save  time  you  can  use  the  same  DMX  address  for  each  fixture.  All  fixtures  will  then  respond  simultaneously  to  cont

rol.  You  may  

also  group  your  fixtures  and  address  those  groups  ali

ke  for  faster  programming  and  control.

  

1.   Access   the   control   panel   function   by   pressing   the   “MENU”   button   until   the   ‘RUN   MODE’   is   displayed.   Press   “ENTER”   and   use   t

he  

“UP/DOWN”  buttons  to  select  ‘DMX’  function.  Then,  Press  “MENU”  button  until  ‘DMX512  ADDR

ESS’  is  displayed.  Use  the  “UP/DOWN”  

buttons  to  increase  or  decrease  channels  between  001  and  512.  2.  Press  the  (ENTER)  button  to  confirm  action.  Then  press  “MENU

”  to  

exit.  Deactivate  ID  addressing  in  each  fixture  by  setting  panel  function  ‘ID  ON/OFF’  to  O

FF.  “SET”  to  “ID  ON/OFF”  to  “OFF”

  

  

DMX

512

  

addressing  with  ID  address

  

1

.  Follow  instructions  

1

    

for  DMX

512

  

addressing.

  

2.   Activate   ID   addressing   in   each   fixture   by   setting   panel   function   “ID   ON/OFF”   to   ON.   “Settings”   to   “ID   ON/OFF”   to   “ON”   For  

every  

DMX512

  

starting   address   the   user   can   set  

66

  

separate   ID   addresses.   Set.ID   addresses   in   each   fixture   by   setting   panel   function“ID  

address”  to  incremental  values.(l.e.  

1,12,24,36

  

etc...)  “Settings”  to  “address  ”  to“

01

  

~  

66

  

  

  

  

Setting  the  DMX  address

  

Each  fixture

  

requires  a  start  address  

from  1  to  512.  A  fixture  requiring  one  or  more  channels

  

for  control  begins  to  read  the  data  on  the  

channel  indicated  by  the  start  address.  For  example,  a

  

fixture  that  occupies  or  uses  5  channels  of  DMX  and  was  addressed  to  start  o

n  

DMX  channel

  

100,  would  read  data  from  channels:  100,  101,  102,  103,and  105.  Choose  start  addresses  so

  

that  the  channels  used  do  not  

overlap  and  note  the  start  address  selected  for  future  reference.

  

The  equipment  uses  up  to11channels  of  DMX.  lf  this  is  yo

ur  first  time  

using  DMX,  we  recommend

  

reading  the  DMX  Primer  in  the  Appendix  Section.

  

  

Control  Panel  Functions

  

All  fixture  functions  and  settings  are  accessible  via  the  built

in  control  panel  interface.

  

  

Содержание SIRIUS 21 LED 3W RGB 3in1 IP65

Страница 1: ...User Manual SIRIUS 21 LED 3W RGB IP65 Triton Blue Rev Jan 2014 www triton blue com SIRIUS 21 LED 3W RGB 3in1 IP65 USER MANUAL...

Страница 2: ...contents to ensure that all parts are present and have been received in good condition AC Power This fixture has an auto switching power supply that can accommodate a wide range of input voltages The...

Страница 3: ...ance Do not daisy chain power to more than 10 units 120V and 20 units 230V To prevent or reduce the risk of electrical shock or fire do not expose this unit to rain or moisture There are no user servi...

Страница 4: ...when pr 01 10 is set 3 Green set the fade time when pr 01 11 is set 4 Blue 5 Color change white balance 6 Strobe 7 Auto custom program 8 Speed of auto 10 ID address ARC 1 Channel Description 1 Red 2...

Страница 5: ...ixture for over head use then please follow the below steps 2 Block access below the work area and use suitable and stable platform when installing or servicing fixture 3 Ssfety cables must always be...

Страница 6: ...t Maximum capacitance between conductor and shield _ 55 pF ft Maximum resistance of 20 ohms 1000 ft Nominal impedance 100 _ 140 ohms CABLE CONNECTORS Cabling must have a male XLR connector on one end...

Страница 7: ...r of the next fixture consisting of a male 3 pin connector Then proceed to connect from the output as stated above to the input of the following fixture and so on 4 OPERATING INSTRUCTIONS Control Opti...

Страница 8: ...to exit Deactivate ID addressing in each fixture by setting panel function ID ON OFF to OFF SET to ID ON OFF to OFF DMX 512 addressing with ID address 1 Follow instructions 1 for DMX512 addressing 2...

Страница 9: ...User Manual SIRIUS 21 LED 3W RGB IP65 Triton Blue Rev Jan 2014 www triton blue com...

Страница 10: ...User Manual SIRIUS 21 LED 3W RGB IP65 Triton Blue Rev Jan 2014 www triton blue com...

Страница 11: ...User Manual SIRIUS 21 LED 3W RGB IP65 Triton Blue Rev Jan 2014 www triton blue com...

Страница 12: ...User Manual SIRIUS 21 LED 3W RGB IP65 Triton Blue Rev Jan 2014 www triton blue com...

Страница 13: ...User Manual SIRIUS 21 LED 3W RGB IP65 Triton Blue Rev Jan 2014 www triton blue com DMX512 Chnnnel Values...

Страница 14: ...User Manual SIRIUS 21 LED 3W RGB IP65 Triton Blue Rev Jan 2014 www triton blue com Important Notes about STAG DMX Operation...

Страница 15: ...GB IP65 Triton Blue Rev Jan 2014 www triton blue com MASTER DIMMER Channels 1 control the intensity of the currently projected color When the slider is at the highest position 255 then the intensity o...

Страница 16: ...hose starting address is set incorrectly You can however control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operati...

Отзывы: