![Tritec TRI-KA Скачать руководство пользователя страница 109](http://html1.mh-extra.com/html/tritec/tri-ka/tri-ka_operating-instructions-manual_1168942109.webp)
10.3 evaluation of the measuring results
The current/voltage characteristic curve (I/U characteristic curve)
of a photovoltaic system is used to identify and analyse different
features and problems of a generator. It helps detect partial shad-
ing of the generator field, defective bypass diodes, excessive ad-
ditional module resistance, soiling of the modules and problems
with individual cells in the PV modules. Interpreting characteristic
curves requires some experience and basic knowledge of semicon-
ductor technology. To facilitate the interpretation, examples of
characteristic curves from the evaluation software are compiled
at www.tri-ka.com.
216_Transfer of measuring data
Instructions for use_217
11. insTRUCTiOns FOR Use
11.1 instrument storage and care
Both instruments should always be transported and stored in
their case. The buttons and screens are designed for manual
operation and are not resistant to metal or other hard objects.
Always use a soft cloth to clean the measuring instrument. Harsh
abrasives or aggressive cleaning agents will irreparably damage
the screen and buttons. To prevent damage to the LiPo battery
during longer storage times of the measuring device, the battery
should be charged to app. 50 %.
11.2 Disposal
Before disposal of the TRI-KA, make sure to separate and prop-
erly dispose of the various components and batteries.
english
Содержание TRI-KA
Страница 23: ...Konformitätserklärung_45 44_Konformitätserklärung 13 Konformitätserklärung deutsch ...
Страница 45: ...Déclaration de conformité_89 88_Déclaration de conformité 13 Déclaration de conformité français ...
Страница 67: ...132_Dichiarazione di conformità 13 Dichiarazione di conformità italiano Dichiarazione di conformità_133 ...
Страница 89: ...Declaración de conformidad_177 176_Declaración de conformidad 13 Declaración de conformidad espaÑol ...
Страница 111: ...Declaration of conformity_221 220_Declaration of conformity 13 Declaration of conformity english ...