![Tritec TRI-KA Скачать руководство пользователя страница 108](http://html1.mh-extra.com/html/tritec/tri-ka/tri-ka_operating-instructions-manual_1168942108.webp)
Transfer of measuring data_215
10. TRAnsFeR OF MeAsURing DATA
10.1 Transfer of TRi-sen data to the TRi-KA
The data measured by the TRI-SEN are wirelessly transferred to
the TRI-KA. A wireless connection is automatically established
once both instruments are switched on. The connection is shown
at the top of the screen (picture).
If the wireless connection is disrupted, the data are stored in the
TRI-SEN until they are synchronised. This allows measurement
even without a connection. The disruption of the data connection
is signalled by a message popping up on the TRI-KA screen.
The TRI-SEN should not be switched off before the data have
been transferred, as otherwise all values will be lost and the meas-
urement is no longer reliable.
10.2 Transfer of TRi-KA values to the pC
Once saved, all measured values are automatically stored on the
SD card of the TRI-KA.
The data are uploaded using the TRI-KA PC software and insert-
ing the memory card into the computer or the supplied reader.
More details on how to upload the data are provided in the soft-
ware manual on the SD card.
The software is saved on the sD card of the TRi-KA in the
directory “…\TRi-KA\UpDATe”; it can also be downloaded at
www.tritec-energy.com.
english
214_TRI-SEN – Functions
9.5 Measuring the irradiation
Once the TRI-SEN is switched on, the integrated solar cells meas-
ure the irradiation. After the temperature measurement, the
TRI-SEN is placed in the mounting which is fitted flush with the
modules (chapter 4.5). The position of the TRI-SEN at module lev-
el is crucial for the accuracy and reliability of the STC evaluation!
The irradiation is measured continuously, stored at intervals in the
memory and transferred to the TRI-KA. The current irradiation is
shown in the top left-hand corner of the screen.
9.6 Measuring the angle of inclination
Once switched on, the TRI-SEN continuously measures the angle
of inclination, shown in the top right-hand corner of the screen.
For a reliable measuring result, the TRI-SEN should be placed in
the mounting fitted to the module frame (chapter 4.5).
Содержание TRI-KA
Страница 23: ...Konformitätserklärung_45 44_Konformitätserklärung 13 Konformitätserklärung deutsch ...
Страница 45: ...Déclaration de conformité_89 88_Déclaration de conformité 13 Déclaration de conformité français ...
Страница 67: ...132_Dichiarazione di conformità 13 Dichiarazione di conformità italiano Dichiarazione di conformità_133 ...
Страница 89: ...Declaración de conformidad_177 176_Declaración de conformidad 13 Declaración de conformidad espaÑol ...
Страница 111: ...Declaration of conformity_221 220_Declaration of conformity 13 Declaration of conformity english ...