Important Safety Instructions

SAVE THESE  INSTRUCTIONS

This manual contains important instructions and warnings that should 
be followed during the installation, operation and storage of all Tripp Lite UPS
systems. Failure to follow these warnings will void your warranty.

UPS Location Warnings

• Install your UPS indoors, away from excess moisture or heat, conductive 

contaminants, dust or direct sunlight.

• For best performance, keep the indoor temperature between 32° F and 

104° F (between 0° C and 40° C).

• Leave adequate space around all sides of the UPS for proper ventilation.

UPS Connection Warnings

• Connect your UPS directly to a properly grounded AC power outlet. 

Do not plug the UPS into itself; this will damage the UPS.

• Do not modify the UPS’s plug, and do not use an adapter that would 

eliminate the UPS’s ground connection. 

• Do not use extension cords between the UPS and outlet. Your warranty will 

be voided if anything other than Tripp Lite surge suppressors are used to
connect your UPS to an outlet.  

• If the UPS receives power from a motor-powered AC generator, the generator

must provide clean, filtered, computer-grade output.

Equipment Connection Warning

• Do not use Tripp Lite UPS Systems for life support appliances in which a

malfunction or failure of a Tripp Lite UPS System could cause failure or 
significantly alter the performance of a life-support device.

• Do not connect surge suppressors or extension cords to the output of your

UPS. This might damage your UPS and will void both the surge suppressor
and UPS warranties.

Battery Warnings

• Your UPS does not require routine maintenance. Do not open your UPS 

except to replace batteries. There are no user-serviceable parts inside.

• Battery replacement should be performed by qualified service personnel.

Because the batteries present a risk of electrical shock and burn from high
short-circuit current, service personnel should observe proper precautions.
Use tools with insulated handles, remove all metal hand jewelry and when
possible work with only one hand to reduce the danger of shock. Replace the
existing batteries with an equal number of new batteries of the same type. 
Do not open the sealed lead-acid batteries. Do not short or bridge the battery
terminals with any object.

• The UPS batteries are recyclable. Refer to local codes for disposal require-

ments or in the USA only call 1-800-SAV-LEAD (1-800-728-5323) for 
complete recycling information. Do not dispose of the batteries in a fire.  

• The UPS contains its own energy source (battery). The output terminals may

be live even when the UPS is not connected to an AC supply.

• Only connect Tripp Lite battery packs of the correct voltage to your UPS’s

external battery connectors.

• Do not connect or disconnect external battery packs while the UPS is

operating from battery.

• Do not operate your UPS without batteries.

Содержание SMART 1250XL NET

Страница 1: ...th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com Owner s Manual SmartPro NET SmartPro XL 1250 3000 VA Intelligent Network UPS Systems 120V ESPAÑOL p 8 FRANÇAIS p 15 Installation p 3 4 Basic Operation p 4 6 Storage Service p 7 Specifications p 7 Safety p 2 Warranty Insurance p 6 ...

Страница 2: ...antly alter the performance of a life support device Do not connect surge suppressors or extension cords to the output of your UPS This might damage your UPS and will void both the surge suppressor and UPS warranties Battery Warnings Your UPS does not require routine maintenance Do not open your UPS except to replace batteries There are no user serviceable parts inside Battery replacement should b...

Страница 3: ...he battery charger and microprocessor The XXX light will flash until you engage the ON Standby Switch to activate the ON mode Engage the momentary ON Standby Switch UPS front panel and release it to activate the ON mode and supply power to the UPS receptacles See Figure 2 3 2 1 DB9 Port Connection Optional On Next Page Figure 2 ON Standby Switch Figure 1 DIP Switch 4 System Enable Switch ENABLE DI...

Страница 4: ...232 communications If you have additional computers Connect them to the DB9 ports labeled BASIC which provide basic contact closure shutdown capabili ties Set their corresponding LAN Interface DIP Switches to the ACTIVATE DOWN position See diagram for which switch controls which port Serial port connections are optional Your UPS will function properly without these connections The SMART DB9 port i...

Страница 5: ...icator Lights All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned ON This green light will shine constantly to indicate AC power is available at the receptacles It will flash to indicate AC power is not available See System Enable Switch and ON Standby Switch descriptions above This multi colored light displays 7 separate UPS battery charge conditions It wi...

Страница 6: ... port connects your UPS to any workstation or server Use with Tripp Lite software and 73 0743 cable to monitor and manage network power and automatically save open files and shut down equipment during a blackout This port uses RS 232 com munications to transmit UPS and power conditions Pin 7 Transmit Pin 8 Common Pin 9 Receive Contact Tripp Lite Customer Support for more information and a list of ...

Страница 7: ...toms of the problem If the UPS is within the 2 year warranty period enclose a copy of your sales receipt SMART 2200 NET SMART 3000 NET Output Capacity VA Watts 2200 1700 3000 2400 Battery Runtime Half Load Full Load Minutes 27 11 23 7 Battery Recharge Rate 2 4 hrs 2 4 hrs Suggested Circuit 15 amp or 20 amp dedicated 30 amp dedicated Approvals UL cUL UL cUL SMART 1250XL NET SMART 2200XL NET Output ...

Страница 8: ...1111 W 35th Street Chicago IL 60609 USA 773 869 1234 USA 773 869 1212 International www tripplite com ...

Отзывы: