background image

2

Important Safety Instructions

SAVE THESE  INSTRUCTIONS 

This manual contains instructions and warnings that should be followed during the installation, 
operation and storage of this product. Failure to heed these warnings will void your warranty.

UPS Location Warnings

•  Install the UPS indoors, away from excess moisture, temperature extremes, conductive contaminants, 

dust and direct sunlight.

•  For best performance, keep the indoor temperature between 32º F and 104º F (0º C and 40º C).

•  Leave adequate space around all sides of the UPS for proper ventilation.

•  Do not mount the unit with its front or rear panel facing down (at any angle). Mounting in this 

manner will seriously inhibit the unit’s internal cooling, eventually causing product damage not 
covered under warranty.

UPS Connection Warnings

•  Connect the UPS to a properly grounded AC power outlet. Do not plug the UPS into itself; this will 

damage the UPS.

•  Do not modify the UPS input connector, and do not use an adapter that would eliminate the ground 

connection of the UPS.

•  Do not use extension cords to connect the UPS to an AC outlet. 

•  If the UPS receives power from a motor-powered AC generator, the generator must provide clean, 

fi ltered, computer-grade output.

Equipment Connection Warnings

•  Use of this equipment in life support applications where failure of this equipment can reasonably 

be expected to cause the failure of the life support equipment or to signifi cantly affect its safety 
or effectiveness is not recommended. Do not use this equipment in the presence of a fl ammable 
anesthetic mixture with air, oxygen or nitrous oxide.

•  Do not connect surge suppressors to the output of the UPS. This might damage the UPS and will 

void the surge suppressor and UPS warranties.

Battery Warnings

•  The UPS does not require routine maintenance. There are no user-serviceable parts inside. Do not 

open the UPS for any reason.

•  Batteries present a risk of electrical shock and burns from high short-circuit current. Battery 

replacement should be performed only by authorized service personnel. Observe proper precautions. 
Unplug and turn off the UPS before performing battery replacement. Use tools with insulated 
handles. Replace the existing batteries with the same number and type of batteries (sealed Lead-
Acid). Do not open the batteries. Do not short or bridge the battery terminals with any object. 
Tripp Lite offers a complete line of UPS Replacement Battery Cartridges. Visit 

www.tripplite.com/support/battery

 to locate the specifi c replacement battery for your UPS.

•  The UPS batteries are recyclable. Refer to local codes for disposal requirements. Do not dispose of 

the batteries in a fi re.

•  Do not operate the UPS without batteries. Do not attempt to add external batteries to the UPS.

200704074 93-2671 MINI550X OM.in2   2

200704074 93-2671 MINI550X OM.in2   2

8/2/2007   2:58:43 PM

8/2/2007   2:58:43 PM

Содержание PRO550X

Страница 1: ...1 W 35th Street Chicago IL 60609 USA 1 773 869 1234 www tripplite com Copyright 2007 Tripp Lite All rights reserved All trademarks are the property of their owners Important Safety Instructions 2 Inst...

Страница 2: ...life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not r...

Страница 3: ...begin to charge its battery until it has been turned on Connected equipment will not be supported adequately during a power failure until the internal battery has charged for 4 6 hours It will take u...

Страница 4: ...system will switch to On Battery mode see On Battery Low Battery Overload section below in order to adjust the voltage to a safe level On Battery Low Battery Overload During a utility power failure or...

Страница 5: ...UPS system s ground connection and places connected equipment at risk UPS Cold Start To use the UPS system as a stand alone power source when AC power is unavailable i e during a blackout press the O...

Страница 6: ...can arrange to send you proper packaging Securely pack the UPS to avoid damage during shipping Do not use Styrofoam beads for packaging Any damages direct indirect special incidental or consequential...

Страница 7: ...1111 W 35th Street Chicago IL 60609 USA 773 869 1234 USA 773 869 1212 International www tripplite com...

Отзывы: