Quick Installation (optional)
1
Phone/Network Line Surge Suppression*
Your UPS has jacks which protect against surges
on a phone or network line. Using RJ11 or RJ45
cords, connect your wall jack to the UPS jack
marked IN. Connect your equipment to the UPS
jack marked OUT. Make sure the equipment you
connect to the UPS’s jacks is also protected
against surges on the AC line.
*Not compatible with PoE (Power over Ethernet)
applications.
2
USB Communications
Use any USB cable to connect the USB port of
your computer to the USB port of your UPS.
Download the PowerAlert UPS monitoring software
program appropriate for your operating system
from www.tripplite.com and install it on your
computer.
3
External Battery Connection
(OMNIVSINT1500XL only)
All UPS models come with a robust internal
battery system; select models feature connectors
that accept an optional external battery pack
(available separately from Tripp Lite) to provide
additional runtime. Adding an external battery will
increase recharge time as well as runtime. See
battery pack owner's manual for complete
installation instructions. Make sure cables are
fully inserted into their connectors. Small sparks
may result during battery connection; this is
normal. Do not connect or disconnect battery
pack when the UPS is running on battery power.