background image

7

Important Safety Instructions

•  When connecting or disconnecting power to hot-pluggable power 

supplies, observe the following guidelines:
o  Install the power supply before connecting the power cable to the 

power supply.

o  Unplug the power cable before removing the power supply.
o  If the system has multiple power sources, disconnect power from the 

system by unplugging all power cables from the power supplies.

•  Never push objects of any kind into or through cabinet slots. They may 

touch dangerous voltage points or short out parts, resulting in a risk of 
electrical shock or fire.

•  If the following conditions occur, unplug the device from the wall outlet 

and bring it to qualified service personnel for repair.
o  The power cord or plug has become damaged or frayed.
o  Liquid has been spilled into the device.
o  The device has been exposed to rain or water.
o  The device has been dropped or the cabinet has been damaged.
o  The device exhibits a distinct change in performance, indicating a need 

for service.

o  The device does not operate normally when the operating instructions 

are followed.

•  Only adjust those controls that are covered in the operating instructions. 

Improper adjustment of other controls may result in damage that will 
require extensive work by a qualified technician to repair.

•  This device is designed for IT power distribution systems with up to 230V 

phase-to-phase voltage.

•  To prevent damage to your installation, it is important that all devices are 

properly grounded.

18-06-260-933845-EN.indd   7

8/10/2018   2:43:53 PM

18

Miscellaneous KVM Functionality

2.

  Initiate the session by pressing the following hotkey command, one key 

after another.

[Alt][Alt][c][n][f][g]

3.

  Upon completing the command, the mouse connected to the KVM will 

stop functioning. A prompt will appear to enter the Credential ID.

4.

  Log in by entering the default username 

admin

 and pressing Enter.

5.

  Enter the default password 

12345

 and press Enter.

6.

  Select option 2 from the menu on your screen and press Enter.

7. 

Connect the USB peripheral device to be registered to the console 
USB-A CAC port on the KVM. Wait until the KVM is reading the new 

peripheral information.

8.

  When registration is completed, the KVM will list the information of the 

newly configured peripheral on the screen and vibrate 3 times.

18-06-260-933845-EN.indd   18

8/10/2018   2:43:54 PM

6

Important Safety Instructions

• Read all instructions and save them for future reference.

• F

ollow all warnings and instructions marked on the device.

• Do not place the device on any unstable surface (cart, stand, table, etc.). 

If the device falls, serious damage will result.

• Do not use the device near water

.

• Do not place the device near

, or over, radiators or heat registers. The 

device cabinet contains slots and openings to allow for adequate 

ventilation. To ensure reliable operation and to protect against 

overheating, these openings must never be blocked or covered.

• The device should never be placed on a soft surface (bed, sofa, rug, etc.) 

as this will block its ventilation openings. Likewise, the device should not 

be placed in a built-in enclosure unless adequate ventilation has been 

provided.

• Never spill liquid of any kind on the device.

• Unplug the device from the wall outlet before cleaning. Do not use liquid 

or aerosol cleaners. Use a damp cloth for cleaning.

• The device should be operated from the power source type as indicated 

on the marking label. If you are not sure of the type of power available, 

consult your dealer or local power utility.

• Do not allow anything to rest on the power cord or cables. Route the 

power cord and cables so that they cannot be stepped on or tripped over.

• If an extension cord is used with this device, make sure the total ampere 

rating of all products used on the cord does not exceed the extension 

cord ampere rating. Make sure the total rating of all products plugged into 

the wall outlet does not exceed 15 amperes.

• P

osition system cables and power cables carefully. Make sure nothing 

rests on any cables.

• T

o help protect your system from sudden transient increases and 

decreases in electrical power, it is recommended you plug your devices 

into a Tripp Lite Surge Protector

, Line Conditioner, or Uninterruptible 

Power Supply (UPS).

18-06-260-933845-EN.indd   6

8/10/2018   2:43:53 PM

Содержание B002-DP1A2-N4

Страница 1: ...tripplite com support Ce guide est disponible en fran ais sur le site Web de Tripp Lite www tripplite com support Secure KVM Switches NIAP Protection Profile Version 3 0 DisplayPort Models B002 DP1A4...

Страница 2: ...ree 3 years from the date of initial purchase TRIPP LITE s obligation under this warranty is limited to repairing or replacing at its sole option any such defective products To obtain service under th...

Страница 3: ...Premium High Speed HDMI Cables P782 XXX DH HDMI USB KVM Cable Kit P580 Series DisplayPort Cables U022 Series USB 2 0 A B Device Cables XXX refers to length e g 006 6 ft 010 10 ft and so on 260 933845...

Страница 4: ...emoving these labels will void the warranty 260 933845 EN indd 4 8 10 2018 2 43 5 DisplayPort DVI or HDMI monitor Note The number of displays needed can be determined from the model name The number di...

Страница 5: ...re EDID Emulation Secure EDID learning and emulation prevents unwanted and unsecure data from being transmitted through the DDC line Automatic Keyboard Buffer Clearing The keyboard buffer is automatic...

Страница 6: ...evice from the wall outlet before cleaning Do not use liquid or aerosol cleaners Use a damp cloth for cleaning The device should be operated from the power source type as indicated on the marking labe...

Страница 7: ...it to qualified service personnel for repair o The power cord or plug has become damaged or frayed o Liquid has been spilled into the device o The device has been exposed to rain or water o The devic...

Страница 8: ...he USB input ports of the KVM Switch Note Models with CAC Common Access Card support require an additional USB 2 0 A B cable connected to each computer 3 Using 3 5 mm stereo audio cables connect the a...

Страница 9: ...are not supported 7 For models with CAC support connect a CAC reader to the console CAC port of the KVM switch Note CAC readers with external power sources are not supported 8 Power on the KVM by con...

Страница 10: ...al CAC device is connected When the LED is flashing a non CAC peripheral is connected 260 933845 EN indd 14 8 10 2018 2 43 5 18 06 2 14 KVM LEDs Port Selection LEDs When the LED is off the correspondi...

Страница 11: ...intended for the system administrator The Event Log is a detailed report of critical activities stored in the KVM or KVM memory To view or dump the Event Log follow the instructions below Note Only on...

Страница 12: ...n for download instructions The Administration and Security Management screen will appear Miscellaneous KVM Functionality 260 933845 EN indd 20 8 10 2018 2 43 5 18 06 12 RESET Restore Factory Defaults...

Страница 13: ...ity can be found in the Administrator s Guide available at www tripplite com support Power Up Self Test If all front panel LEDs are on and not flashing the Power Up Self Test failed and all functions...

Страница 14: ...and place of purchase This warranty does not apply to equipment which has been damaged by accident negligence or misapplication or has been altered or modified in any way EXCEPT AS PROVIDED HEREIN TR...

Страница 15: ...23 260 933845 EN indd 23 8 10 2018 2 43 5 53 PM 15...

Страница 16: ...18 06 2 24 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 18 06 260 93 3845_RevB 260 933845 EN indd 24 8 10 2018 2 43 5 16...

Отзывы: