UPS Location Warnings

• Install your UPS indoors, away from excess moisture or heat, conductive contaminants,

dust or direct sunlight.

• For best performance, keep the indoor temperature between between 32º F and 104º F

(0º C and 40º C).

• Leave adequate space around all sides of the UPS for proper ventilation.

UPS Connection Warnings

• The UPS contains its own energy source (battery). The output terminals may be live even

when the UPS is not connected to an AC supply.

• Do not operate your UPS without connecting its input and output grounds.

• If the UPS receives power from a motor-powered AC generator, the generator must 

provide clean, filtered, computer-grade output.

Equipment Connection Warnings

• Do not use Tripp Lite UPS Systems for life support applications in which a malfunction 

or failure of a Tripp Lite UPS System could cause failure or significantly alter the 
performance of a life-support device.

Battery Warnings

• Your UPS does not require routine maintenance. Do not open your UPS for any reason

except battery replacement. There are no user-serviceable parts inside.

• Battery replacement must be performed by qualified service personnel. Because the 

batteries present a risk of electrical shock and burn from high short-circuit current,
observe proper precautions. Unplug and turn off the UPS before performing battery
replacement. Use tools with insulated handles, and take caution that the battery terminals
do not contact the metal housing of the UPS. Replace the existing batteries with the
same number and type of new batteries (Sealed Lead-Acid). Do not open the batteries.
Do not short or bridge the battery terminals with any object.

• The UPS batteries are recyclable. Refer to local codes for disposal requirements, or in

the USA only call 1-800-SAV-LEAD for recycling information. Do not dispose of the
batteries in a fire. 

• Do not attempt to add external batteries to your UPS system.

SAVE THESE  INSTRUCTIONS

This manual contains instructions and warnings that should be followed during the 
installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these
warnings will void your warranty.

Important Safety Instructions

200208100 93-2041 OM500RMX Manual.qxd  9/11/2002  3:08 PM  Page 2

Содержание 500 VA

Страница 1: ...ns 2 Mounting 3 Connection 4 Basic Operation 5 Storage and Service 8 Copyright 2002 Tripp Lite All rights reserved OmniSmart is a trademark of Tripp Lite OmniSmart RMX 500 VA 120V Input Output UPS System Intelligent Line Interactive Industrial Cabinet Specifications 8 200208100 93 2041 OM500RMX Manual qxd 9 11 2002 3 08 PM Page 1 ...

Страница 2: ...ept battery replacement There are no user serviceable parts inside Battery replacement must be performed by qualified service personnel Because the batteries present a risk of electrical shock and burn from high short circuit current observe proper precautions Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles and take caution that the battery termin...

Страница 3: ...ount Installation Mounting Suggested DIN Rail Installation DIN RAIL DIN MOUNT BRACKET 1 1 2 Attach the DIN mounting brackets A to the mounting ears by lining the brackets captive nuts up with the mounting ears holes then attaching them with the bolts provided B Attach mounting ears C to the rear mounting holes of the UPS using the screws provided D Note that there is a left mounting bracket and a ...

Страница 4: ...o the GROUND OUT green yellow terminal Connect the incoming hot wire to the HOT IN brown terminal Connect the incoming neutral wire to the NEUTRAL IN blue terminal Connect the outgoing hot wire to the HOT OUT black terminal Connect the outgoing neutral wire to the NEUTRAL OUT white terminal Turn utility power on Your UPS will enter STANDBY mode The LINE POWER LED will begin flashing The UPS system...

Страница 5: ...tteries but its output is not active Pressing the POWER button while the UPS is in STANDBY mode will put the UPS in the ON mode Cutting AC power to the UPS while it is in STANDBY mode will put the UPS in the OFF mode ON The light is on The UPS is receiving AC power charging its batteries and delivering power to connected equipment If AC power is lost while the UPS is ON i e a blackout occurs the U...

Страница 6: ...the load on the UPS If the LOW BATTERY alarm a constant beep sounds your UPS s batteries may need replacing or the batteries may simply be less than fully charged Let the UPS charge for twelve hours then perform a second self test If the LOW BATTERY alarm sounds again contact Tripp Lite for service LINE POWER This green light will turn ON whenever your UPS is receiving normal AC line power It will...

Страница 7: ...omatically save open files and shut down equip ment during a blackout see Connection page 4 Battery Door Qualified service personel can remove this plate to remove and replace the UPS batteries All Battery Warnings must be observed see Important Safety Warnings page 2 Automatic Voltage Regulation Internal During brownouts your UPS will automatically correct low AC line voltage When automatic volta...

Страница 8: ...gulated Output Voltage Range 120 9 On Battery Output Voltage Range 115 5 Output Waveform Line Mode filtered sinewave Output Waveform Battery Mode PWM sine wave AC Surge Suppression exceeds IEEE 587 Cat A B standards AC Noise Attenuation 40 dB AC Surge Protection Modes H to N H to G N to G This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This...

Отзывы: