background image

Installed whole system
total rack space height
(rack spaces)

2U

Secondary form factor

Tower (requires 

2-9USTAND

)

UPS / Power Module weight
(lbs)

43.5

UPS / Power Module weight
(kg)

19.7

UPS Shipping dimensions
(height x width x depth /
inches)

9 x 24 x 20.2

UPS Shipping dimensions
(height x width x depth / cm)

22.9 x 61 x 51.4

Shipping weight (lbs)

53

Shipping weight (kg)

24.1

UPS housing material

Steel

Cooling method

Fan

ENVIRONMENTAL

Operating Temperature
Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC mode BTU / hr. (full
load)

34.3

Battery mode BTU / hr. (full
load)

463.6

COMMUNICATIONS

Communications interface

USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface

Network monitoring port
description

Supports detailed monitoring of UPS and site power conditions

PowerAlert software

Included

Communications cable

USB and DB9 cabling included

WatchDog compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

LINE / BATTERY TRANSFER

Transfer time

2-4 milliseconds

Low voltage transfer to
battery power (setpoint)

75

High voltage transfer to
battery power (setpoint)

147

SPECIAL FEATURES

Grounding lug

Back panel grounding lug

Cold Start (startup in
battery mode during a
power failure)

Cold-start operation supported

Содержание 1500RMXL2UA

Страница 1: ...DB9 monitoring ports Includes PowerAlert UPS monitoring and unattended shutdown software with complete cabling Built in accessory slot supports SNMP with optional SNMPWEBCARD adapter Emergency Power Off EPO interface offers option for instantaneous power off of UPS and connected equipment in the case of fire or emergency Multi function audible alarms and set of 5 front panel LEDs offer at a glance...

Страница 2: ... compatibility 60 Hz Output voltage regulation line mode 18 8 Output voltage regulation Battery mode 5 Built in UPS output receptacles 8 5 15R outlet s Built in controllable switched load banks Three switchable two outlet 5 15R load banks Output AC waveform AC mode Sine wave Output AC waveform battery mode Pure Sine wave INPUT Rated input current at maximum load 10 1A Nominal Input Voltage s Suppo...

Страница 3: ...ate line power battery power overload voltage regulation and battery low replace status Alarms Audible alarm indicates power failure overload and low battery conditions Alarm cancel operation Power fail alarm can be silenced using alarm cancel switch once silenced alarm will re sound to indicate low battery status Switches 2 Switches control off on power status and alarm cancel self test operation...

Страница 4: ...idity 0 to 95 non condensing AC mode BTU hr full load 34 3 Battery mode BTU hr full load 463 6 COMMUNICATIONS Communications interface USB DB9 Serial EPO emergency power off Slot for SNMP Web interface Network monitoring port description Supports detailed monitoring of UPS and site power conditions PowerAlert software Included Communications cable USB and DB9 cabling included WatchDog compatibilit...

Страница 5: ... Duty 14AWG Power cord IEC 320 C13 to NEMA 5 15P 1 Power Cables P010 012 12 ft 18AWG Power cord NEMA 5 15P to IEC 320 C13 1 Power Cables P022 001 1 ft 18AWG Power Extension cord NEMA 5 15R to NEMA 5 15P 1 Power Cables P023 001 1 ft 14AWG Power Adapter cord NEMA L5 15R to NEMA 5 15P 1 Power Cables P034 010 10 ft 14AWG Heavy Duty Power cord IEC 320 C19 to NEMA 5 15P 1 Power Distribution PDU1215 Basi...

Страница 6: ...KITWM Enables 2 Post Rackmount or Wallmount Installation of Select Rackmount UPS Systems 1 Replacement Batteries RBC93 2U 2U UPS Replacement Battery Cartridge for select Tripp Lite SmartPro UPS 1 SNMP Accessories ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires SNMPWEBCARD or switched PDU 1 SNMP Accessories SNMPWEBCARD For remote monitoring and control via SNMP Web or ...

Отзывы: