Maintenance 

  

Cleaning and storage 

 

o  The meter should be cleaned with a damp cloth and mild 

detergent when necessary. Do not use solvents or abrasives. 

 

p  Store the meter in an area with moderate temperature and 

humidity (refer to the operating and storage range in the 
specifications chart earlier in this manual). 

 

Battery Replacement 

 

When the battery power falls low, the battery symbol will 
appear on the LCD. Replace the 9 Volt battery by removing 
the Philips head screw holding the rear battery compartment 
cover to access the battery compartment. Ensure that the 
compartment cover is securely fastened when finished. 

 

You, as the end user, are legally bound (

Battery ordinance

to return all used batteries and accumulators; 

disposal in the 

household garbage is prohibited! 

 

You can hand over your used batteries / accumulators 
at collection points in your community or wherever 
batteries / accumulators are sold! 

 

Disposal: 

Follow the valid legal stipulations in respect of the 

disposal of the device at the

 

end of its lifecycle 

 
 
 
 
 
 
 
 
 
 

 

Содержание RHT60

Страница 1: ...recision Psychrometer 5 Commonwealth Ave 5 Commonwealth Ave Woburn MA 01801 Woburn MA 01801 Phone 781 665 1400 Phone 781 665 1400 Toll Toll Free 1 800 517 8431 Free 1 800 517 8431 Visit us at www Test...

Страница 2: ...Off and MAX MIN reading Meter Description 1 Humidity and Temperature Sensor 2 LCD Display 3 Power ON OFF Button 4 MIN MAX Button 5 F C WBT Wet Bulb Dew Point button 6 HOLD Backlight Button Note The b...

Страница 3: ...Humidity measurement appears in the top display 4 Pressing the F C WBT Dew Point button toggles the lower display between Temperature F Temperature C Dew Point C Dew Point F Wet Bulb C and Wet Bulb F...

Страница 4: ...is now displayed Temperature measurements 1 To select the temperature measurement press the F C WBT Dew Point button until C or F appears in the lower right 2 Temperature is now displayed Data Hold Pr...

Страница 5: ...ing in the bottom display The display will not change until a lower reading is registered To exit the MIN MAX mode press and hold the MIN MAX button for 2 seconds until the MAX or MIN icon disappears...

Страница 6: ...hen the battery power falls low the battery symbol will appear on the LCD Replace the 9 Volt battery by removing the Philips head screw holding the rear battery compartment cover to access the battery...

Страница 7: ...0o C 158 1 to 199 0o F Wet Bulb 0 to 80 C 32 to 176 F Calculated from RH and air Dew Point 30 to 100 C 22 to 199 F temperature measurements Display Dual LCD Response Time 30 seconds 90 of final value...

Страница 8: ...ly to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as in our sole judgment to injure their stability or rel...

Отзывы: