Condensation Mode 

 

The Condensation feature alerts the user when the surface temperature 
as measured by the IR thermometer is close to or has reached the Dew 
Point temperature. 

 

1. 

Press the power 

 button to turn the meter on. 

 

2. 

Press the COND button

. The “COND” icon will appear. 

 

3. 

Point the meter at a surface, press the IRT button to measure the 

surface temperature. The small display will indicate the IR surface 
temperature and the large display will indicate the difference 
between the IR temperature and the Dew Point temperature. 

 

4. 

The meter will then report the potential for condensation on that 

surface in the following manner 

If the temperature of the IRT is more than 14°C (25°F) 
above the Dew Point, the temperature difference shall be 
displayed, with no other warning. 

 

If the temperature of the IRT is 3-14°C (5-25°F) above the Dew Point, 
the temperature difference shall be displayed, along with a standard 
Condensation Indicator icon. The meter shall beep once to confirm 
that the reading is in the risk area. 

 

If the temperature of the IRT is less than 3°C (5°F) above the Dew 
Point, the temperature difference shall be displayed, along with a 
flashing Condensation Indicator icon. The meter shall beep twice to 
confirm that the reading is in the high-risk area. 

 

5. 

Press the RH button to exit the mode. 

 

 

Vapor Pressure Mode 

 

Ambient Vapor Pressure 

 

1. 

With the Condensation mode active, press the COND button to display 

the Vapor Pressure in mBAR (°F) or kPa (°C). Press the ▲or ▼button 
to toggle between mBAR or kPa. 

2. 

Press the REL MOIST or RH button to exit the Vapor Pressure mode. 

 

Surface Vapor Pressure 

 

Содержание MS475

Страница 1: ...lus IR Thermometer Monitor moisture in wood and other building materials with no surface damage with the Pinless Moisture sensor Pin type Moisture Probe included Measure Humidity and Air Temperature w...

Страница 2: ...COND Condensation Button 5 RH Relative Humidity Button 6 MOIST REL Button 7 DOWN ZERO Button 8 UP UNIT Button 9 Memory Store Enter ALARM Set Button 10 IR Thermometer Button 11 ON OFF Button 12 Pinles...

Страница 3: ...tion 6 Low battery indication 7 GPP unit indication Grains Per Pound 8 MAX MIN indication 9 Condensation mode symbol 10 VPP unit indication Vapor Pressure 11 GPP unit indication 12 Humidity bar displa...

Страница 4: ...ure plus Grains Per Pound GPP and Dew Point DP Ambient and Surface Vapor Pressure Automatic calculation of differential Temperature IR DP Min Max and Data Hold 20 point internal memory Auto power off...

Страница 5: ...e and to return to the normal mode 6 If the humidity measurement is higher than the LOW alarm setting the meter will beep once every second 7 If the humidity measurement is higher than the HIGH alarm...

Страница 6: ...r approximately 10 seconds before returning to ambient temperature measurement IRT MAX MIN display The meter can be set to display only the maximum or minimum temperature measured during an IR scan 1...

Страница 7: ...ew Point the temperature difference shall be displayed with no other warning If the temperature of the IRT is 3 14 C 5 25 F above the Dew Point the temperature difference shall be displayed along with...

Страница 8: ...ay stored readings The numeric display above the MEM icon will flash 2 Use the or button to scroll through the memory locations 3 To return to normal operating mode press the STORE button Clearing Sto...

Страница 9: ...to 1 C 9 F 5 C D S 8 1 32 F 0 C 1 8 F 1 C Emissivity 0 95 Fixed 33 to 392 F 1 to 200 C 3 6 F 2 2 C Display 3 digit primary display 4 digit secondary display Vapor Pressure 0 to 20 0kPA calculated fro...

Страница 10: ...hese goods for use Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of 1 one year from the date of pu...

Отзывы: