Triplett MS475 Скачать руководство пользователя страница 5

Operation 

 

 

Powering the meter 

 

1. 

Remove the RH sensor protective cap before use. 

 

2. 

Press the power 

 button to turn the meter on. 

 

3. 

If the 

 symbol appears or the meter does not turn on, replace the battery. 

 

Humidity (Dew point, GPP, g/kg) Measurements 

 

1. 

Press the power 

 button to turn the meter on. 

 

2. 

Press the RH button 

 

3. 

Relative Humidity will be displayed in the primary display and the ambient temperature will be 
displayed in the secondary display. 

 

4. 

Press the RH button to select a display of DEW Point Temperature (DP) or Grains Per Pound 
(GPP) . 

 

5. 

Press and HOLD the UNITS button to toggle between °F or °C. (GPP or g/kg) 

 

Humidity Alarm Set Procedure: 

 

1. 

Press the button until the buzzer rings and Release button, the meter shall enter Humidity 
Alarm Set mode, the 

“HIGH” icon appears on the LCD.  

2. 

Press the ▲or ▼button to set the high limit desired. 

3. 

Press the STORE/ENTER button to save the value and proceed to the LOW set value. 

 

4. 

With the “LOW” icon in the display, Press the ▲or ▼button to set the low limit desired. 

 

5. 

Press the STORE/ENTER button to save the value and to return to the normal mode. 

 

6. 

If the humidity measurement is higher than the LOW alarm setting, the meter will beep once 

every second 

7. 

If the humidity measurement is higher than the HIGH alarm setting, the meter will beep 
continuously. 

8. 

The ambient Temperature or dew point temperature shall be displayed in °F or °C by pressing 

/UNIT button for 3 to toggle between °F/°C. (GPP or g/kg) 

 

 

 

Pinless Moisture Measurements 

 

1. 

Press the power 

 button to turn the meter on. 

 

2. 

Press the REL 

button to select Moisture measurement.” MOIST”, and “INT” (internal pinless 

sensor) will appear in the display. 

 

3. 

Hold the meter so that the rear sensor is away from any surface or your hand. The reading 
should be near 0.0. If not, press and hold the ZERO button for more than 2 second and the 
ZERO icon appears. 

 

4. 

Place the rear sensor on the surface of the material to be tested and read the relative moisture 
content. 

 

Pin Type Moisture Measurements 

 

1. 

Connect the external pin probe to the jack on the bottom of the meter. 

 

2. 

Press the power 

 button to turn the meter on. 

 

3. 

Press the REL 

button twice to select Moisture measurement.” MOIST”, and “EXT” (external 

pin probe) will appear in the display. 

 

4. 

Press the probe pins into the material and read the % moisture content in the display. 

Содержание MS475

Страница 1: ...lus IR Thermometer Monitor moisture in wood and other building materials with no surface damage with the Pinless Moisture sensor Pin type Moisture Probe included Measure Humidity and Air Temperature w...

Страница 2: ...COND Condensation Button 5 RH Relative Humidity Button 6 MOIST REL Button 7 DOWN ZERO Button 8 UP UNIT Button 9 Memory Store Enter ALARM Set Button 10 IR Thermometer Button 11 ON OFF Button 12 Pinles...

Страница 3: ...tion 6 Low battery indication 7 GPP unit indication Grains Per Pound 8 MAX MIN indication 9 Condensation mode symbol 10 VPP unit indication Vapor Pressure 11 GPP unit indication 12 Humidity bar displa...

Страница 4: ...ure plus Grains Per Pound GPP and Dew Point DP Ambient and Surface Vapor Pressure Automatic calculation of differential Temperature IR DP Min Max and Data Hold 20 point internal memory Auto power off...

Страница 5: ...e and to return to the normal mode 6 If the humidity measurement is higher than the LOW alarm setting the meter will beep once every second 7 If the humidity measurement is higher than the HIGH alarm...

Страница 6: ...r approximately 10 seconds before returning to ambient temperature measurement IRT MAX MIN display The meter can be set to display only the maximum or minimum temperature measured during an IR scan 1...

Страница 7: ...ew Point the temperature difference shall be displayed with no other warning If the temperature of the IRT is 3 14 C 5 25 F above the Dew Point the temperature difference shall be displayed along with...

Страница 8: ...ay stored readings The numeric display above the MEM icon will flash 2 Use the or button to scroll through the memory locations 3 To return to normal operating mode press the STORE button Clearing Sto...

Страница 9: ...to 1 C 9 F 5 C D S 8 1 32 F 0 C 1 8 F 1 C Emissivity 0 95 Fixed 33 to 392 F 1 to 200 C 3 6 F 2 2 C Display 3 digit primary display 4 digit secondary display Vapor Pressure 0 to 20 0kPA calculated fro...

Страница 10: ...hese goods for use Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of 1 one year from the date of pu...

Отзывы: