5.1 

Display: ..............................  0.5" (12mm) high LCD  

5.2 

Display Resolution: ...........  2000 counts, 0000 to 1999 

5.3 

Overrange Indication: ........  First digit displays "1",          

                                                                   remaining digits are blank 
5.4 

Measurement Rate: ............  2 to 3 measurements per second 

5.5 

Low Power Annunciator: ... 

 

5.6 

Case Dimensions: ..............  5.4 x 3.1 x 1.6 inches (L x W x H) 

 

(including boot)      

      

5.7 

Weight with battery: ......… 0.55 lbs. 

 (including 

boot) 

   

5.8 

Power Source: ..................  9 volt battery 

5.9a  

Overvoltage Category: .....  Category II (CAT II) IEC 1010, 300V     

                     (Installation Category)        AC/DC.  For measuring local level,   
                                                                 appliances, portable equipment, etc. For     
                                                                 applications where transient voltages 
                                                                 are not present, or are of low amplitude.   
                                                                 Not for use in high energy industrial  
                                                                 installation measurement. Not for use on       
                                                                 circuitry where source capability exceeds  
                                                                 4KW.

 

 

5.9b  

Overvoltage Category: ..  Category I (CAT I) IEC 1010, 600VDC,  

                                                              600VAC.  For measuring in low power   
                                                              consumer electronics where transient  
                                                              voltages are not present. Not for use in high  
                                                              energy industrial installation measurement.  
                                                              Not for use on circuitry where source  
                                                              capability exceeds 4KW. 

Applies to 

Voltage 

Measurement 

Only 

  5:  

SPECIFICATIONS

Applies to 

Voltage 

Measurement 

Only 

 
5.10 Fuses: 

............ 

mA 

Jack:  300mA / 500V, 5 x 20mm:  3207-130 

 

 

   10A Jack:  UNFUSED 

5.11 

Supplied Accessories: ...  Boot: 10-4271 

   Test 

Leads: 

79-760 

   Temperature 

Probe: 

79-795 

   Instruction 

Manual: 

84-848 

 
 
 
 

 

Содержание 1101-A

Страница 1: ...TRIPLETT MODEL 1101 A 1...

Страница 2: ...Model 1101 A is a 3 1 2 digit handheld Digital Multimeter with a backlit LCD display At its core is an LSI Large Scale Integration integrated circuit which uses dual slope A D conversion for stability...

Страница 3: ...ommendations of any Trade Organizations or Regulatory Agencies whose scope encompasses the use of this meter 2 6 Do not open this meter for maintenance without first disconnecting the test leads from...

Страница 4: ...ltages to the input of the meter which are elevated above the earth ground potential by more than 600VDC AC peak Doing so may damage the meter and or injure the user 2 21 Do not continue to use meter...

Страница 5: ...es These charges may be of lethal potential and may have enough energy to cause damage to the meter or injury to the user These capacitors can store electricity even when the circuitry which they are...

Страница 6: ...the user to misinterpret the hazards present For example the meter may indicate a low voltage when high voltages are actually present 2 46 Avoid usage near strong electrostatic fields high voltage pow...

Страница 7: ...Use caution and follow instructions and warnings to avoid electric shock Failure to do so may result in user injury GROUND The voltage rating associated with this symbol identifies the maximum allowa...

Страница 8: ...git resolution 2000 counts 4 4 Backlit LCD display 4 5 Protective shock absorbing boot 4 6 Diode Test 4 7 Continuity Beeper 4 8 Transistor Gain Test 4 9 Temperature Measurement 4 10 Fused A mA ranges...

Страница 9: ...cations where transient voltages are not present or are of low amplitude Not for use in high energy industrial installation measurement Not for use on circuitry where source capability exceeds 4KW 5 9...

Страница 10: ...0M Overload Protection 500Vrms AC Voltage Range Resolution Accuracy 200V 100mV 500V 1V 1 2 rdg 10 digits Input Impedance All ranges are approx 5M Frequency 40Hz to 400Hz Overload Protection 200mV is 2...

Страница 11: ...s Overload Protection 500Vrms Thermocouple K Type Note The provided thermocouple is only intended to measure Temperatures up to 300 degrees F Exceeding this temperature may damage the probe Diode Test...

Страница 12: ...ight and Hold button 3 Rotary Function Range Selector Switch 4 Transistor Test Jack 5 COM Jack Common black jack for all measurements 6 10A Jack Input for currents from 200mA to 10A 7 V mA F Jack Inpu...

Страница 13: ...magnitude of the voltage is unknown set the RANGE switch to the 500 position If the input voltage is higher than 500VDC or exceeds the limitations of a CAT I 600V measurement do not attempt to measur...

Страница 14: ...meter The fact that the meter displays the voltages does not mean that it is safe to measure these voltages 7 2 1 Connect the black test lead to the COM jack and the red test lead to the V mA F jack 7...

Страница 15: ...rements Do not attempt to measure current in a circuit whose open circuit voltage exceeds 500V 7 3 1 Connect the black test lead to the COM jack Connect the red test lead to the 10A jack unless it is...

Страница 16: ...red test lead to the V mA F jack 7 4 2 Set the RANGE switch to the position that is appropriate for the device or circuit to be measured The LCD display will indicate overrange i e 1 7 4 3 Connect the...

Страница 17: ...he resistance of the device or circuit being measured 7 6 Diode Test WARNING Do not apply voltage or current to the meter when it is set to the Diode Test Continuity Beeper mode 7 6 1 Connect the blac...

Страница 18: ...F jack 7 7 2 Set the RANGE switch to the degree F range 7 7 3 Press the tip of the thermocouple probe against the surface to be measured The tip may also be immersed in non corrosive liquids 7 8 Trans...

Страница 19: ...acklight comes on Release the button The backlight will stay on for about 20 seconds and then turn itself off 8 2 Hold A Hold feature is incorporated into the 1101 A It is a momentary Hold feature tha...

Страница 20: ...ase remove the rubber bumpers that cover the case screws Remove the screws 9 1 2 Gently open case starting at the bottom where the screws were removed 9 1 3 When the back of the case is removed remove...

Страница 21: ...d in the warranty 9 4 Service TRIPLETT PRODUCT RETURN INSTRUCTIONS In the unlikely event that you must return your Triplett equipment for repair the following steps must be taken 1 Call 1 800 TRIPLETT...

Страница 22: ...ole judgment to injure their stability or reliability or which have been subject to misuse abuse misapplication negligence accident or which have had the serial numbers altered defaced or removed Acce...

Страница 23: ...er person is authorized to extend the liability of Triplett Corporation in connection with the sale of its products beyond the terms hereof Triplett Corporation reserves the right to discontinue model...

Страница 24: ...24...

Отзывы: