WARNING!!! 

This meter is NOT to be used to measure High Energy circuits (power 

circuitry fused at greater than 4KW, such as distribution circuits, 

power entrance circuits, etc.) or circuits classified by CE as 

CATEGORY III (CAT III).

 

 
2.1  

Read all instructions in this manual before using this meter. 

2.2 

Prior to using the meter in any situation which could result in injury 
to the user, in order to verify that the meter is functional and 
producing a valid reading, test the meter on a circuit(s) known to have 
potentials equivalent to the potential that is to be measured. For 
example, before using the meter to determine if an AC power line is 
energized with 120VAC, test the meter on a line known to be 
energized with 120VAC.  

2.3 

Do not use this meter with its battery cover open, its rear case open, 
or with parts removed. Doing so may damage the meter and/or injure 
the user.  

 

2.4 

When using this meter in schools and workshops, responsible teachers 
or skilled personnel must control the usage of this meter. 

2.5 

Follow the recommendations of any Trade Organizations or 
Regulatory Agencies whose scope encompasses the use of this meter. 

2.6 

Do not open this meter for maintenance without first disconnecting 
the test leads from all external circuitry.  

2.7 

Repairs and maintenance must only be carried out by qualified service 
personnel or qualified electricians / technicians who know the dangers 
of, and the safety rules applicable to this type of equipment. 

2.8 

Always set the meter to the appropriate range or mode before 
connecting it to the circuitry to be tested. 

2.9 

Check the condition of the test leads before making a measurement. 
Do not use the test leads if there is damaged insulation or exposed 
metal.  

2.10  

Make sure test leads are properly inserted and seated in the meter's 
input jacks. A loose test lead may cause the user to believe that no 
hazard exists, when in fact, dangerous voltages or currents may be 
present. 

2.11 

Do not touch the tips of the test leads when making a measurement. 
Do not touch live circuitry when making a measurement. 

2.12 

Before using the meter, examine both the meter and the test leads for 
damage. Do not use the meter if damage (damaged insulation, 
exposed metal, cracked case, burnt smell, etc.) is evident. 

 

3

Содержание 1101-A

Страница 1: ...TRIPLETT MODEL 1101 A 1...

Страница 2: ...Model 1101 A is a 3 1 2 digit handheld Digital Multimeter with a backlit LCD display At its core is an LSI Large Scale Integration integrated circuit which uses dual slope A D conversion for stability...

Страница 3: ...ommendations of any Trade Organizations or Regulatory Agencies whose scope encompasses the use of this meter 2 6 Do not open this meter for maintenance without first disconnecting the test leads from...

Страница 4: ...ltages to the input of the meter which are elevated above the earth ground potential by more than 600VDC AC peak Doing so may damage the meter and or injure the user 2 21 Do not continue to use meter...

Страница 5: ...es These charges may be of lethal potential and may have enough energy to cause damage to the meter or injury to the user These capacitors can store electricity even when the circuitry which they are...

Страница 6: ...the user to misinterpret the hazards present For example the meter may indicate a low voltage when high voltages are actually present 2 46 Avoid usage near strong electrostatic fields high voltage pow...

Страница 7: ...Use caution and follow instructions and warnings to avoid electric shock Failure to do so may result in user injury GROUND The voltage rating associated with this symbol identifies the maximum allowa...

Страница 8: ...git resolution 2000 counts 4 4 Backlit LCD display 4 5 Protective shock absorbing boot 4 6 Diode Test 4 7 Continuity Beeper 4 8 Transistor Gain Test 4 9 Temperature Measurement 4 10 Fused A mA ranges...

Страница 9: ...cations where transient voltages are not present or are of low amplitude Not for use in high energy industrial installation measurement Not for use on circuitry where source capability exceeds 4KW 5 9...

Страница 10: ...0M Overload Protection 500Vrms AC Voltage Range Resolution Accuracy 200V 100mV 500V 1V 1 2 rdg 10 digits Input Impedance All ranges are approx 5M Frequency 40Hz to 400Hz Overload Protection 200mV is 2...

Страница 11: ...s Overload Protection 500Vrms Thermocouple K Type Note The provided thermocouple is only intended to measure Temperatures up to 300 degrees F Exceeding this temperature may damage the probe Diode Test...

Страница 12: ...ight and Hold button 3 Rotary Function Range Selector Switch 4 Transistor Test Jack 5 COM Jack Common black jack for all measurements 6 10A Jack Input for currents from 200mA to 10A 7 V mA F Jack Inpu...

Страница 13: ...magnitude of the voltage is unknown set the RANGE switch to the 500 position If the input voltage is higher than 500VDC or exceeds the limitations of a CAT I 600V measurement do not attempt to measur...

Страница 14: ...meter The fact that the meter displays the voltages does not mean that it is safe to measure these voltages 7 2 1 Connect the black test lead to the COM jack and the red test lead to the V mA F jack 7...

Страница 15: ...rements Do not attempt to measure current in a circuit whose open circuit voltage exceeds 500V 7 3 1 Connect the black test lead to the COM jack Connect the red test lead to the 10A jack unless it is...

Страница 16: ...red test lead to the V mA F jack 7 4 2 Set the RANGE switch to the position that is appropriate for the device or circuit to be measured The LCD display will indicate overrange i e 1 7 4 3 Connect the...

Страница 17: ...he resistance of the device or circuit being measured 7 6 Diode Test WARNING Do not apply voltage or current to the meter when it is set to the Diode Test Continuity Beeper mode 7 6 1 Connect the blac...

Страница 18: ...F jack 7 7 2 Set the RANGE switch to the degree F range 7 7 3 Press the tip of the thermocouple probe against the surface to be measured The tip may also be immersed in non corrosive liquids 7 8 Trans...

Страница 19: ...acklight comes on Release the button The backlight will stay on for about 20 seconds and then turn itself off 8 2 Hold A Hold feature is incorporated into the 1101 A It is a momentary Hold feature tha...

Страница 20: ...ase remove the rubber bumpers that cover the case screws Remove the screws 9 1 2 Gently open case starting at the bottom where the screws were removed 9 1 3 When the back of the case is removed remove...

Страница 21: ...d in the warranty 9 4 Service TRIPLETT PRODUCT RETURN INSTRUCTIONS In the unlikely event that you must return your Triplett equipment for repair the following steps must be taken 1 Call 1 800 TRIPLETT...

Страница 22: ...ole judgment to injure their stability or reliability or which have been subject to misuse abuse misapplication negligence accident or which have had the serial numbers altered defaced or removed Acce...

Страница 23: ...er person is authorized to extend the liability of Triplett Corporation in connection with the sale of its products beyond the terms hereof Triplett Corporation reserves the right to discontinue model...

Страница 24: ...24...

Отзывы: