D01-905en201912 Manual eCHEM Free Chlorine

General Information 

//

 Free Chlorine

1.3 Warnings

• 

The sensor should only be used in drinking water, swimming pool water or sea water, other water qualities should  

 

be tested.

•  

Any other use is considered improper. In the event of improper use, all warranty claims are void and liability is  

 excluded. 

•  

The sensor may only be used to determine and control the concentration of free chlorine.

•  

The sensor is not suitable for checking the absence of chlorine.

•  

The material resistance should be tested for each application. 

•  

Do not cut, damage or change the cable. Make sure that no heavy objects are placed on the cable and that the  

 

cable is not kinked. Make sure that the cable is not run near hot surfaces. 

•  

Do not place any unsuitable objects near the measuring head as long as the measurement process is running,  

 

as this can cause damage to the membrane or incorrect measurement results. 

•  

Stop operation of the sensor in the event of excessive heat development (i.e. if it is hot to the touch). Switch off  

 

the sensor immediately and unplug the cable from the power supply. Please contact your dealer or the TriOS  

 

customer service. 

•  

Never try to disassemble or modify the electrode body of the sensor if such a procedure is not explicitly  

 

described in this manual. Inspections, modifications and repairs may only be carried out by the dealer or  

 

by qualified experts authorized by TriOS. 

•  

If the associated cable is damaged, it must be replaced with an original part by the customer service of  

 

TriOS GmbH. 

•  

When installing the sensor outside Germany, the relevant national regulations must be observed.

•   

No liability is assumed for personal injury or damage to property resulting from non-observance of these  

 

operating instructions, modification of the sensor or its improper use. 

•  

Devices from TriOS Mess- und Datentechnik GmbH meet the highest safety standards. Repairs to the device  

 

(which involve the replacement of the connecting cable) must be carried out by TriOS Mess- und Datentechnik  

 

GmbH or by a workshop authorized by TriOS. Defective, improper repairs can lead to accidents and injuries.

Do not touch the electrode finger or otherwise contaminate it! Do not remove the coating of the 

electrode finger!

1.4 User and Operating Requirements

The chlorine sensor has been developed for use in industry and science. The implementation of chlorine determination with 
test kits often requires the handling of hazardous substances. 

We assume that the operating personnel are familiar with dealing with dangerous substances based on their professional 
training and experience. The operating personnel must be able to correctly understand and implement the safety labels and 
information on the packaging and in the package inserts of the test kits.

TriOS does not guarantee the plausibility of the measured values. The user is always responsib-

le for the monitoring and interpretation of the measured values.

NOTICE

DANGER

Содержание Free Chlorine

Страница 1: ...Free Chlorine OPERATING INSTRUCTIONS...

Страница 2: ......

Страница 3: ...11 4 Use 12 4 1 Installation with Retaining Ring 14 4 2 Installation without Retaining Ring 15 5 Calibration 16 5 1 Manufacturer Calibration 16 5 2 Customer calibration 16 5 3 Measurement properties 1...

Страница 4: ...cessories supplied by TriOS Mess und Datentechnik GmbH must be installed and operated in accordance with the specifica tions provided by TriOS Mess und Datentechnik GmbH All parts were designed and te...

Страница 5: ...lt in a malfunction of the sen sor Avoid using the following devices in the same room as the TriOS sensor mobile phones cordless phones transmitters receivers and other electrical devices that produce...

Страница 6: ...manual Inspections modifications and repairs may only be carried out by the dealer or by qualified experts authorized by TriOS If the associated cable is damaged it must be replaced with an original...

Страница 7: ...omer service of TriOS Mess und Datentechnik GmbH support trios de According to current scientific knowledge the device is safe to use when it is handled according to the instructions in this user manu...

Страница 8: ...k GmbH products have a label which clearly shows the product designation There is also a rating plate on the sensor with the following information that you can use to uniquely identify the product Ser...

Страница 9: ...ine sensor is a membrane covered potentiostatic 3 electrode measuring cell with a specially arranged counter electrode The measuring electrode is covered by a membra ne and together with the reference...

Страница 10: ...y with water Consult an ophthalmologist if the eyes are reddened The use of warm water is recommended for rinsing off the gel electrolyte residues on the electrode finger and in the membrane cap Gel e...

Страница 11: ...When unscrewing the filled membrane cap be sure to push the hose ring to the side at the marked valve opening so that air can flow into the electrolyte chamber otherwise the membrane will be destroyed...

Страница 12: ...ert the connector into one of the supplied TriOS cables 2 m Additional cable lengths of 0 3 m 2 m 5 m 10 m 25 m are offered Connect the male end of the cable into the connector on the sensor by making...

Страница 13: ...s in the flow cell type FLC see chapter 4 The use of the sensor in other flow cells must be approved byTriOS GmbH Otherwise no warranty will be given for the proper functioning of the sensor or for re...

Страница 14: ...n In case of strong over metering the DPD 1 measurement can remain colourless because the dye is bleached by the chlorine present Before installing the sensor in the flow cell type FLC the system must...

Страница 15: ...FAQ Technical Data Warranty Customer service Contact Keyword Index Accessories D01 905en201912 Manual eCHEM Free Chlorine Free Chlorine Use Screw connection 1 1 4 Approx 122 80 00 Dimensions in mm 18...

Страница 16: ...connection and attach to the sensor as shown in the figure below 3 Before inserting the sensor into the flow cell prepare the flow cell for commissioning according to chapter 3 1 and ensure that the r...

Страница 17: ...ion without Retaining Ring If the sensor is not equipped with a retaining ring slide ring and O ring it can also be installed in the flow cell using an O ring and 2 slide rings The 2nd slide ring is t...

Страница 18: ...on Recommendation Weekly control if necessary more frequently In case of a necessary recalibration operation with a TriOS controller is recommended An integrated wizard guides the user step by step th...

Страница 19: ...inflow velocity 15 L h is required The flow rate must be constant The service life of the membrane is typically 1 year but it depends very much on the water quality Heavy soiling of the membrane must...

Страница 20: ...ater outlet 3 Remove the electrical connection 6 1 Cleaning and Upkeep To ensure a long service life of the chlorine sensor it should be checked regularly for contamination Carefully rinse off any soi...

Страница 21: ...and fill the membrane cap with electrolyte bubble free see section 3 1 If the sensor then still indicates too low or unstable values a new membrane cap must be used 6 2 2 Membrane cap replacement It i...

Страница 22: ...unscrew the membrane cap rinse the membrane cap and electrode holder with clean water and dry in a dust free place The dry membrane cap is then screwed loosely onto the electrode shaft to protect the...

Страница 23: ...o old Use new DPD chemicals and repeat calibration Deposits on the membrane Replace membrane cap see chapter 6 2 2 Gas bubbles on the outside of the membrane Briefly increase the flow rate check and c...

Страница 24: ...nflow Check system and reduce flow rate Missing galvanic isolation Establish galvanic isolation and if ne cessary send in sensor to the supplier to be checked overhauled The sensor is defective Send i...

Страница 25: ...Troubleshooting on the Sensor If the electrode finger turns shiny silver or white the sensor must be overhauled by the manufacturer Brown grey discolou rations are common Tightness test of mem brane...

Страница 26: ...the sensor in a beaker with clean tap water no disinfectant 4 Stir the sensor in the beaker for approx 30 seconds without creating air bubbles 5 Then let the sensor stand still in the beaker and wait...

Страница 27: ...is safely packed with enough packing material Caution Return shipments without an RMA number cannot be accepted and processed Signal test After zero point test 1 Add some disinfectant containing chlor...

Страница 28: ...ft approx 1 per month Temperature compensation Automatic through integrated temperature sensor Pt100 Housing material Micro porous hydrophilic membrane UPVC stainless steel 1 4571 Dimensions L x Appro...

Страница 29: ...unction In addition to the Modbus RTU various other protocols are available A built in valve allows the use of com pressed air cleaning for the sensors The TriBox3 also offers TCP IP and WLAN networks...

Страница 30: ...ith electrolyte replacement of the reference electrode and cleaning of the electrode tip with fine sandpaper The warranty is subject to the following conditions The device and all accessories must be...

Страница 31: ...lorine Customer Service 10 Customer service If you are having a problem with the sensor please contact TriOS customer service We recommend sending the sensor in for maintenance and calibration every 2...

Страница 32: ...Chlorine 11 Contact We are constantly working to improve our devices Visit our website for news and information If you have found an error or bug in one of the devices or programs please let us know...

Страница 33: ...Malfunction and Maintenance Comm issioning Introduction General Information FAQ Technical Data Warranty Customer service Contact Keyword Index Accessories D01 905en201912 Manual eCHEM Free Chlorine Fr...

Страница 34: ...Bypass installation 12 C Care 18 CE certification 34 Cleaning 18 Contact 30 Copyright 2 Customer calibration 16 Customer service 29 D Declaration of conformity 5 Disposal 5 E Electrical installation 1...

Страница 35: ...905en201912 Manual eCHEM Free Chlorine Free Chlorine Keyword Index P Product Identification 6 Q R Rating plate 6 Reagents 3 Retaining ring 14 Returns 25 RMA number 25 S Safety instructions 3 Scope of...

Страница 36: ...the product TriOS GmbH d clare la conformit du produit Bezeichnung eCHEM Freies Chlor Product name eCHEM Free Chlorine Designation Typ Type Type Art Nr 90S210001 Mit den folgenden Bestimmungen 2014 30...

Страница 37: ...Sensor type CL4 1 M1 0x04 R O Int Hardware 1120 1 120 0x06 R O Int Firmware 1202 1 202 Modbus sensor short data Electrochemical sensor with digital signal processing and Modbus RTU interface Power su...

Страница 38: ...4 mg L 5 ppb 6 g L 0x0201 R O int Measurement range 0 0000 1 000 0 2 00 00 3 0 000 3 0x0206 R W float X_Null 0x0208 R W float X_Span 0x020a R W unsigned longint DateTime yymmddhhmm History 0x0210 R O...

Страница 39: ...sensor electronics accepts the new calibration data if the date stamp is sent within approx 5 seconds following the values If the date differs from that of the last calibration the new values are stor...