Comfort

BREEZE 

TM

 Model CB707

I n s t a l l a t i o n ,   O p e r a t i o n ,   &   M a i n t e n a n c e   M a n u a l

4

www.trioniaq.com

3. Introduction

The  benefits  of  a  properly  humidified  environment  (35-55% 

Relative Humidity) are many. They include both personal com-

fort as well as the preservation of furniture, draperies, car

-

pets, wooden floors and cabinets, paintings, pianos, etc. Your 

home  can  be  more  comfortable  at  a  lower  temperature  (i.e.: 

68° F) at 30-40% Relative Humidity (RH) than at 71° to 72° F 

without controlled humidity. Since every degree of tempera

-

ture  setback  represents  about  3%  of  your  heating  costs,  this 

can  represent  a  significant  annual  savings.  During  the  heat-

ing season, cold air infiltrates the home and must be heated. 

When heated, this air dries out and greatly increases its 

capacity  to  hold  more  moisture.  By  using  a  humidifier,  a 

source of water is provided to satisfy this increased mois

-

ture holding capacity, rather than having it drawn from oc

-

cupants and the surrounding furnishings in the home.

3.1 Basic Operation

Your Comfort

BREEZE

TM

 centrifugal atomizing humidifier oper-

ates on the principles of atomization and evaporation.  A rotating 

impeller pulls water from a small reservoir and slings it against 

a periphery of impaction posts inside the unit.  The force of the 

impact causes the water to break into tiny droplets which are 

subsequently discharged from the unit into the air.  Once the 

atomized water has exited the unit, it evaporates and raises the 

relative humidity of the air.

If applicable, set the humidistat in the recommended range of 

30-40% relative humidity for automatic humidity control during 

the heating season. A lower setting may be necessary to pre-

vent condensation on windows.  If needed, an electronic humidi

-

stat is available to automatically reset the humidity setpoint as 

the outside air temperature changes.  

During the first heating season, check the reservoir for mineral 

build-up periodically to establish a cleaning schedule.  Clean the 

unit at the end of each heating season, or whenever mineral de

-

posits appear to be impeding the performance of the humidifier.

When shutting the humidifier down for the summer months, start 

by cleaning and mineral accumulation from the unit.  Turn the 

water off to the unit and dry any remaining water from the reser

-

voir.  See Page 8 for End Of Season Decommissioning.

3.2 “What’s In The Box?”

Part Number

Description

265562-001 or 265562-002

CB707 Humidifier

265160-001

Humidistat

265310-001

Wall/Duct Mount Bracket

266152-002

Nozzle Extension Tube

265631-001

IOM Manual

266004-001

Parts Bag

Hareware Details:

(1) Plug-in Elbow Tube Fitting 1/2” X 1/2”
P/N: 265570-001

Use: Attaches to the drain connection on the bottom of the unit 

for shelf mounted applications.

(4) #10 X 1/2” Plastite Screw & Rubber Feet
P/N: 265378-226 & 266201-001

Use: Attaches to the bottom of the base

(6) #12 X 3/4” TEK Screw & #12 Flat Washer
P/N: 60645 & 120031-010

Use: Secures flange and mounting bracket to duct.

(2) 1/4” X 2” Lag Screw & 1/4” Flat Washer
P/N: EST-175 & 120031-011

Use: Attaches mounting bracket to wall stud.

(2) #10-32 X 1” Pan Head Screw, #10 Flat washer, & #10-32 

Nyloc Nut

P/N: 137790-310, 120031-009, & 123149-008

Use: Attaches unit to the mounting bracket.

Содержание ComfortBREEZE CB707

Страница 1: ...T r i o n w w w t r i o n i a q c o m ComfortBREEZE TM CB707 Centrifugal Atomizing Humidifier READ AND SAVE THESE INSTRUCTIONS...

Страница 2: ...4 3 3 What s in the Box 4 3 4 Hardware Details 4 4 Installation 5 4 1 Clearances 5 4 2 Selecting a location 5 4 2 1 Wall Mounting 5 4 2 2 Duct Mounting 6 4 2 3 Ceiling Mouning 6 4 2 4 Shelf Mounting...

Страница 3: ...is limited to replacement of defective parts or components and does not include the pay ment of the cost of labor charges to remove or replace such defec tive components or parts 7 Trion will not be r...

Страница 4: ...f the air If applicable set the humidistat in the recommended range of 30 40 relative humidity for automatic humidity control during the heating season A lower setting may be necessary to pre vent con...

Страница 5: ...ic dispersion it may be hung from a ceiling mounting hardware not included for this type of installation or it may be simply mounted to a shelf An indicating LED is located on the oposite side of the...

Страница 6: ...ounting holes as shown on the template for mounting the bracket to the duct 5 Cut out the discharge hole while taking care not to injure yourself Once the hole is cut out ensure that the edges will no...

Страница 7: ...ge the water into a bucket or pan This will allow the water to flush any debris that may have accumulated in the line during the in stallation process Once this is complete close the saddle valve 3 At...

Страница 8: ...up for continu ous operation by installing a jumper between the H terminals on the control board you must remove the jumper wire placed between terminals H1 H2 on the control board 5 3 End of Season...

Страница 9: ...at care is taken not to damage bend or break the atomizing posts 7 Remove the cover from the electrical box and unwire the line cord and humidistat wires from the terminals It is not necessary to remo...

Страница 10: ...logged solenoid valve or flow restrictor c Leaking reservoir d Bad control board 2 Red LED blinking repeatedly 1 second On 1 second OFF Unit will not function B Float switch not closing in 30 minutes...

Страница 11: ...ler tube Motor will not operate turn Motor internal thermal protective device is open Remove power and allow motor to cool Restart unit and ensure proper operation If motor will not turn replace motor...

Страница 12: ...1 19 G 109 G 109 SOLENOID VALVE ASSEMBLY 1 20 165001 001 PUSH TO LOCK MALE ELBOW 1 4 X 1 8 NPT 1 21 265305 001 FILL FITTING 1 8 NPT 2 22 166129 001 SCREW 8 X 3 8 PH PH THRD CUT SST 7 23 265378 220 SC...

Страница 13: ...SHOWN 2 54 266793 001 FEMALE THREADED STANDOFF 1 55 266455 001 CONTROL BOARD BRACKET RH 1 56 266455 002 CONTROL BOARD BRACKET LH 2 57 266792 001 LOCKNUT PG9 1 58 266826 001 INLET RING 1 59 265442 001...

Страница 14: ...ComfortBREEZE TM Model CB707 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 14 www trioniaq com See Note 2 on page 13...

Страница 15: ...ComfortBREEZE TM Model CB707 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 15 www trioniaq com...

Страница 16: ...ComfortBREEZE TM Model CB707 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 16 www trioniaq com...

Страница 17: ...ComfortBREEZE TM Model CB707 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 17 www trioniaq com...

Страница 18: ...Form No 265631 001 rev 01 15 2013 Trion 2013 All Rights Reserved Trion 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com...

Отзывы: