T r i o n
®
| w w w. t r i o n i a q . c o m
Comfort
BREEZE
TM
CB707
Centrifugal Atomizing Humidifier
READ AND SAVE THESE INSTRUCTIONS
Страница 1: ...T r i o n w w w t r i o n i a q c o m ComfortBREEZE TM CB707 Centrifugal Atomizing Humidifier READ AND SAVE THESE INSTRUCTIONS...
Страница 2: ...4 3 3 What s in the Box 4 3 4 Hardware Details 4 4 Installation 5 4 1 Clearances 5 4 2 Selecting a location 5 4 2 1 Wall Mounting 5 4 2 2 Duct Mounting 6 4 2 3 Ceiling Mouning 6 4 2 4 Shelf Mounting...
Страница 3: ...is limited to replacement of defective parts or components and does not include the pay ment of the cost of labor charges to remove or replace such defec tive components or parts 7 Trion will not be r...
Страница 4: ...f the air If applicable set the humidistat in the recommended range of 30 40 relative humidity for automatic humidity control during the heating season A lower setting may be necessary to pre vent con...
Страница 5: ...ic dispersion it may be hung from a ceiling mounting hardware not included for this type of installation or it may be simply mounted to a shelf An indicating LED is located on the oposite side of the...
Страница 6: ...ounting holes as shown on the template for mounting the bracket to the duct 5 Cut out the discharge hole while taking care not to injure yourself Once the hole is cut out ensure that the edges will no...
Страница 7: ...ge the water into a bucket or pan This will allow the water to flush any debris that may have accumulated in the line during the in stallation process Once this is complete close the saddle valve 3 At...
Страница 8: ...up for continu ous operation by installing a jumper between the H terminals on the control board you must remove the jumper wire placed between terminals H1 H2 on the control board 5 3 End of Season...
Страница 9: ...at care is taken not to damage bend or break the atomizing posts 7 Remove the cover from the electrical box and unwire the line cord and humidistat wires from the terminals It is not necessary to remo...
Страница 10: ...logged solenoid valve or flow restrictor c Leaking reservoir d Bad control board 2 Red LED blinking repeatedly 1 second On 1 second OFF Unit will not function B Float switch not closing in 30 minutes...
Страница 11: ...ler tube Motor will not operate turn Motor internal thermal protective device is open Remove power and allow motor to cool Restart unit and ensure proper operation If motor will not turn replace motor...
Страница 12: ...1 19 G 109 G 109 SOLENOID VALVE ASSEMBLY 1 20 165001 001 PUSH TO LOCK MALE ELBOW 1 4 X 1 8 NPT 1 21 265305 001 FILL FITTING 1 8 NPT 2 22 166129 001 SCREW 8 X 3 8 PH PH THRD CUT SST 7 23 265378 220 SC...
Страница 13: ...SHOWN 2 54 266793 001 FEMALE THREADED STANDOFF 1 55 266455 001 CONTROL BOARD BRACKET RH 1 56 266455 002 CONTROL BOARD BRACKET LH 2 57 266792 001 LOCKNUT PG9 1 58 266826 001 INLET RING 1 59 265442 001...
Страница 14: ...ComfortBREEZE TM Model CB707 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 14 www trioniaq com See Note 2 on page 13...
Страница 15: ...ComfortBREEZE TM Model CB707 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 15 www trioniaq com...
Страница 16: ...ComfortBREEZE TM Model CB707 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 16 www trioniaq com...
Страница 17: ...ComfortBREEZE TM Model CB707 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 17 www trioniaq com...
Страница 18: ...Form No 265631 001 rev 01 15 2013 Trion 2013 All Rights Reserved Trion 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com...