Operation

Operation:

The Comfort-D is designed to deliver dehumidified, filtered air to the living space, 

and is equipped with an onboard humidistat and fan control and can be equipped 

with various accessories to enhance its operation, including a remote humidistat, 

and your system may incorporate any or all of the described operational compo-

nents�

It is recommended that the indoor environment maintain a maximum relative hu

-

midity level of 50% to 60%�  Other factors may dictate a relative humidity level 

different than the recommended, such as musical instruments, antiques, books/

papers, or special situations�  Winter minimum humidity levels of 30-35% may not 

be  attainable  without  supplemental  humidification  (Humidifier),  and  may  not  be 

desired during times of low outdoor temperatures�   

System Variations:

Humidity Control - Standard:

The system may be installed as free standing or incorporate ducting to an area or 

existing heating/cooling system.  Control is provided by Humidistat with a dial stem 

type adjustment built into the unit.  Set the desired humidity set point by turning 

the dial stem flat to the corresponding set point indicated on the face of the unit.   

This humidity control unit will operate the compressor and circulation fan when the 

dehumidification system is activated, working only when there is a call, or demand 

for dehumidification.  

Remote Humidity Control (Wall Mounted):

When a remote Humidistat is utilized, set the unit mounted humidistat to the “OFF” 

position� 

This control provides the same control functions as above but with greater preci-

sion and can be located in the space for easier access, and may included addi-

tional features�  Available as an accessory item these controls may have different 

features; refer to instructions included with the control�

Typical system operation sequence:

Upon the relative humidity exceeding the humidistat set point, normally by approxi

-

mately  3%,  the  humidistat  will  energize  the  dehumidification  and  air  circulation 

components of the Comfort-D� If the Comfort-D system is connected and inter-

locked with an existing Heating/Air Conditioning system, this systems circulation 

fan will also be energized� The Comfort-D will continue to operate until the humidity 

level is reduced to the set point selected on the humidistat and then will cycle off�  

During this cycle, the air circulated through the Comfort-D system will be filtered 

and dehumidified. If an outside ventilation air duct has been installed, fresh air will 

be filtered and dehumidified and introduced to the space during this cycle.    

Содержание Comfort-D75

Страница 1: ...16 Whole House Central Dehumidifier Comfort D TM Models D75 and D95 266314 301 05 12 Please complete the following on the day of the installation Homeowner to retain for their future informational pur...

Страница 2: ...the entire home s air can a balance between humidity levels temperature comfort and energy costs be optimized Introduction Contents The following items should be included with your Trion Comfort D De...

Страница 3: ...Service Access Adjustable Legs 1 4 1 Low Voltage Terminal Strip Humidistat Blower Control TOP VIEW FRONT VIEW RIGHT SIDE LEFT SIDE BACK VIEW D E Dimension Table Comfort D75 Comfort D95 A 27 25 inch 2...

Страница 4: ...5 x14 25 Filter Dims LxWxH 11 75 x11 75 x2 00 13 75 x13 75 x2 00 Filter Efficiency MERV 11 MERV 11 Compressor Size 5 8 HP 3 4 HP Fan Motor Size 90 W 115 W Airflow 0 0 inch H2O esp 280 CFM 375 CFM Airf...

Страница 5: ...n pan MUST be placed under the unit if installed above a living area or above an area where water leakage could cause damage see local codes for other requirements 6 DO NOT position the Comfort D dire...

Страница 6: ...the return ducting is adequate tap into the existing return duct system near the return air grill Duct the supply of the Comfort D System to the return ducting of the existing HVAC system The fan int...

Страница 7: ...tions return ducting is not necessary Supply duct ing is recommended to enhance the performance of the system a minimum length of supply duct 3 to 6 will aid in air distribution If the area s being se...

Страница 8: ...de of the system For returns less than 10 feet in length an 8 D75 or 10 D95 round or equal may be utilized Multiple returns are acceptable The supply air outlet and the return air inlet are located on...

Страница 9: ...G R W Y Existing Field Supplied Control Wiring Typ Field Supplied Control Wiring DisconnectExisting Control Wiring From Fan G Control Terminal Reconnectto Blue Wire From Comfort D ConnectBrown Wire F...

Страница 10: ...Interlock C R D G Terminal on existing Thermostat G Terminal on Furnace or Air Handler 24V Hot R Terminal on Furnace or Air Handler Low Voltage Terminal R C H D G Remove Existing Wire Betw een T stat...

Страница 11: ...ifier Blower InterLock Connections Low Voltage Fa n Co il Air Ha n d le r Co n tr o l Th e r m o sta t Typ G R W Y G R W Y Existin g Fie ld Su p p lie d Co n tr o l Wir in g Typ Fie ld Su p p lie d Co...

Страница 12: ...he Comfort D and the control or damage to the transformer may result When a remote Humidistat is utilized set the unit mounted humidistat to the OFF position Consult the electrical schematic in this m...

Страница 13: ...dity control unit will operate the compressor and circulation fan when the dehumidification system is activated working only when there is a call or demand for dehumidification Remote Humidity Control...

Страница 14: ...e the loading and correct replacement intervals Your installation contractor should be contacted for assistance To access the air filter remove the filter access panel from the Front or Back side of t...

Страница 15: ...citor 7 266314 042 266314 043 Fan Run Capacitor 8 N A N A Drain Plug 3 4 MNPT 9 266314 051 266314 051 Curtis Terminal Block 10 266314 061 266314 061 Leveling Mount Foot Base 11 N A N A Evaporated Coil...

Страница 16: ...service dealer or contractor in your area or contact Trion IAQ 101 McNeill Road Sanford NC 27330 WARRANTY LIMITATIONS 1 This warranty is void if the covered equipment is removed from the original ins...

Отзывы: