background image

MOTION COORDINATOR 

MC508

Quick Connection Guide

This guide must be used in conjunction with the Technical Reference Manual

8 PNP or NPN inputs 

including

 8 registration inputs

8 PNP or NPN inputs

2 Analogue Inputs,

8 Digital Outputs,

WDOG relay

Micro SD CARD

Ethernet programming, 

Modbus-TCP, Ethernet IP, Trio 

Activex, UNIPLAY HMI

RS232 / RS485 Modbus-

rtu, hostlink or user 

programmable

Backlit Display and

status LEDs

Panel Mount and DIN 

Rail Mount

8 Digital Outputs

ON COORDINA

8 MDR Type Flexible Axis Connectors 

Comprising; Encoder I/O or 2X Step 

/ Dir Channels, Voltage Output, 2x 

Limit Inputs, Enable Output 

CAN port for trio CAN i/o, 

DEVICENET slave, canopen or 

user programmable

Содержание MC508

Страница 1: ...G relay Micro SD CARD Ethernet programming Modbus TCP Ethernet IP Trio Activex UNIPLAY HMI RS232 RS485 Modbus rtu hostlink or user programmable Backlit Display and status LEDs Panel Mount and DIN Rail Mount 8 Digital Outputs ON COORDINA 8 MDR Type Flexible Axis Connectors Comprising Encoder I O or 2X Step Dir Channels Voltage Output 2x Limit Inputs Enable Output CAN port for trio CAN i o DEVICENET...

Страница 2: ...nnection between the chassis earth screw and the earthed metal mounting panel plate The CAN connections are optional See the Technical Reference Manual for important power connection EMC information 5 WAY CONNECTOR A standard Ethernet connector is provided for use as the primary programming interface The Trio programming software Motion Perfect must be installed on a Windows based PC that is fitte...

Страница 3: ...1 6 5V Output 150mA max 7 RS485 Data Out Z Tx Serial Port 2 8 RS485 Data Out Y Tx 8 7 6 5 4 3 1 2 PNP current sink operation Connect common to 0V NPN current source operation Connect common to 24V Any input 0 7 may be mapped to any axis as a registration input Input Common A N C Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Optical Input Signal Common Input 6k8 ...

Страница 4: ...nput 15 OP 0V A OP 24V A output channel 8 output channel 9 output channel 10 output channel 11 output channel 12 output channel 13 output channel 14 output channel 15 24V Power Outputs 8 15 op 0V B op 24V B output 16 output 17 output 18 output 19 output 20 output 21 output 22 output 23 WDOG WDOG analogue 0V Ain 0 analogue 0V Ain 1 WDOG Outputs Analogue Intputs 24V must be applied to power the outp...

Страница 5: ...t will be open circuit if there is no power on the controller OR the user program sets it open with the WDOG OFF command Each axis also has an independent enable relay which operates in tandem with the main relay as determined by the application program See MC4 range technical manuals for details ALL STEPPER AND SERVO AMPLIFIERS MUST BE INHIBITED WHEN THE AMPLIFIER ENABLE OUTPUT IS OPEN CIRCUIT AN...

Страница 6: ...A B Common 11 Enc Z n Enable n Pulse n 8 Data n 12 Enc Z n Enable n Pulse n 8 Data n 13 NC NC Dir n 8 NC 14 NC NC Dir n 8 NC 15 0V Enc 16 Do not connect 17 VOUT n 18 VOUT n 19 Do not connect 20 Input B 17 n 2 Shell Screen FLEXIBLE AXIS CONNECTOR 1 10 11 20 1 n axis number 2 WDOG n normally open solid state relay rated 24V 100mA one per axis 3 Input A B Common 0V_Enc VOUT are all isolated so must b...

Страница 7: ...s is 192 168 0 250 This can be changed using the ETHERNET or the IP _ ADDRESS command via Motion Perfect Good quality screened cables should be used for the serial ports The serial ports and CANbus port are not galvanically isolated therefore the 0V return MUST be connected to all peripheral devices In addition bond together the 0V 24V return terminals of all system components so as to minimise cu...

Страница 8: ...UK USA CHINA INDIA WWW TRIOMOTION COM T H E M O T I O N S P E C I A L I S T quick start v1 January 2016 ...

Отзывы: