TMCM-6110 TMCL Firmware V1.31 Manual (Rev. 1.09 / 2015-FEB-24)
85
www.trinamic.com
L
R
SAP 193, 0, 6
right limit / end / stop switch
: reference search speed (axis parameter 194)
: reference switch speed (axis parameter 195)
Search home switch in positive direction, reverse direction in case right stop switch is hit
start
stop
home switch
Figure 5.7: Search home switch in positive direction, reverse direction in case right stop switch is hit
L
R
SAP 193, 0, 7
: reference search speed (axis parameter 194)
: reference switch speed (axis parameter 195)
Search home switch in negative direction, ignore end switches
start
stop
home switch
Figure 5.8: Search home switch in negative direction, ignore end switches
L
R
SAP 193, 0, 8
: reference search speed (axis parameter 194)
: reference switch speed (axis parameter 195)
Search home switch in positive direction, ignore end switches
start
stop
home switch
Figure 5.9: Search home switch in positive direction, ignore end switches