TMCM-6110 TMCL Firmware V1.31 Manual (Rev. 1.09 / 2015-FEB-24)
72
www.trinamic.com
Number Axis Parameter Description
Range [Unit]
Acc.
6
Absolute max.
current
(CS / Current
Scale)
The maximum value is 255. This value means
100% of the maximum current of the module.
The current adjustment is within the range 0…
255 and can be adjusted in 32 steps.
The most important motor setting, since too
high values might cause motor damage!
0… 7
79…87
160… 167
240… 247
8… 15
88… 95
168… 175
248… 255
16… 23
96… 103
176… 183
24… 31
104… 111
184… 191
32… 39
112… 119
192… 199
40… 47
120… 127
200… 207
48… 55
128… 135
208… 215
56… 63
136… 143
216… 223
64… 71
144… 151
224… 231
72… 79
152… 159
232… 239
0… 255
RWE
7
Standby current The current limit two seconds after the motor
has stopped.
0… 255
RWE
8
Target pos.
reached
Indicates that the actual position equals the
target position.
0/1
R
9
Ref. switch
status
The logical state of the reference home
switch.
0/1
R
10
Right limit
switch status
The logical state of the (right) limit switch.
0/1
R
11
Left limit switch
status
The logical state of the left limit switch (in
three switch mode)
0/1
R
12
Right limit
switch disable
If set, deactivates the stop function of the
right switch
0/1
RWE
13
Left limit switch
disable
Deactivates the stop function of the left
switch resp. reference switch if set.
0/1
RWE
130
Minimum speed Should always be set 1 to ensure exact
reaching of the target position. Do not
change!
0… 2047
RWE
135
Actual
acceleration
The current acceleration (read only).
0… 2047
*
R
138
Ramp mode
Automatically set when using ROR, ROL, MST
and MVP.
0: position mode. Steps are generated, when
the parameters actual position and target
position differ. Trapezoidal speed ramps are
provided.
2: velocity mode. The motor will run
continuously and the speed will be changed
with constant (maximum) acceleration, if the
parameter target speed is changed.
For special purposes, the soft mode (value 1)
with exponential decrease of speed can be
selected.
0/1/2
RWE