Operational Ratings
The operational ratings shown below should be used as design values. In no case should the maximum
values been exceeded during operation.
Symbol
Parameter
Min
Typ
Max
Unit
+U
Driver
/ +U
Logic
Power supply voltage for operation
18
24 or 48
55
V DC
I
COIL_peak
Motor coil current for sine wave
peak
(chopper regulated, adjustable via
software)
0
7.8
A
I
COIL_RMS
Continuous motor current (
RMS
)
0
5.5
A
I
SUPPLY
Power supply current
<< I
COIL
1.4 * I
COIL
A
T
ENV
Environment temperature at rated
current (no forced cooling required)
-20
+50
*)
°C
Table 6.1 General operational ratings of the module
*) The controller driver electronics has been tested inside a climate chamber running at full current (5.5A
RMS) for 30min without air convection at 50°C environmental temperature.
The motor might heat up well above 50°C when running at full current without proper cooling. This might
substantially increase the environmental temperature for the electronics. When using the
coolStep operation
mode
, the actual current might be substantially less than programmed max. current producing and
temperature.