TMCM-1180 and PD86-1180 Hardware Manual (V1.05 / 2013-JUL-26)
19
www.trinamic.com
5
Jumpers
Most settings of the board are done through the software. Nevertheless, a few jumpers are available for
configuration.
CAN bus
termination
RS485 bus
termination
Figure 5.1 RS485 and CAN bus termination
5.1
RS485 Bus Termination
The board includes a 120 Ohm resistor for proper bus termination of the RS485 interface. When this jumper
is closed, the resistor will be placed between the two differential bus lines RS485+ and RS485-.
5.2
CAN Bus Termination
The board includes a 120 Ohm resistor for proper bus termination of the CAN interface. When this jumper is
closed, the resistor will be placed between the two differential bus lines CAN_H and CAN_L.