2400 Pa Load
5400 Pa Load
M
oun
ting
sy
st
em
Clamping s
yst
em
Attachment to the long frame
Clamping s
yst
em
Attachment to the short fra
me
Other mounting configurations can be used however, failure to comply with the above recommendations will result in a
lowering of the load handling (snow/wind load) capabilities below the product specification 5400/2400Pa and product
failure as a result of an overload situation will not be covered by the guarantee.
6.2.
GROUNDING
All module frames and mounting racks must be properly grounded in accordance with appropriate respective
National Electrical Code.
Proper grounding is achieved by bonding the module frame(s) and all metallic structural members together
continuously using a suitable grounding conductor. The grounding conductor or strap may be copper, copper alloy,
or any other material acceptable for use as an electrical conductor per respective National Electrical Codes. The
grounding conductor must then make a connection to earth using a suitable earth ground electrode.
Trina Solar modules can be installed with the use of third party listed grounding devices for grounding the metallic
frames of PV modules. The devices have to be installed in accordance with the grounding device manufacturer’s
specified instructions.
6.3.
MODULE WIRING
All wiring should be performed, by qualified installers, in accordance with the local codes and regulations.
Modules can be connected in series to increase the operating voltage by plugging the positive plug of one module
into the negative socket of the next. Before connecting modules always ensure that the contacts are corrosion free,