2400 Pa Load 

 

5400 Pa Load 

 

M

oun

ting

 sy

st

em 

 

Clamping s

yst

em 

Attachment to the long frame 

 

 

Clamping s

yst

em 

Attachment to the short fra

me 

 
 
 
 

 
 
 
 

Other mounting configurations can be used however, failure to comply with the above recommendations will result in a 
lowering of the load handling (snow/wind load) capabilities below the product specification 5400/2400Pa and product 
failure as a result of an overload situation will not be covered by the guarantee. 

6.2.

 

GROUNDING 

 

All module frames and mounting racks must be properly grounded in accordance with appropriate respective 
National Electrical Code. 

 

Proper grounding is achieved by bonding the module frame(s) and all metallic structural members together 
continuously using a suitable grounding conductor. The grounding conductor or strap may be copper, copper alloy, 
or any other material acceptable for use as an electrical conductor per respective National Electrical Codes. The 
grounding conductor must then make a connection to earth using a suitable earth ground electrode. 

 

Trina Solar modules can be installed with the use of third party listed grounding devices for grounding the metallic 
frames of PV modules. The devices have to be installed in accordance with the grounding device manufacturer’s 
specified instructions. 

6.3.

 

MODULE WIRING 

 

All wiring should be performed, by qualified installers, in accordance with the local codes and regulations. 

 

Modules can be connected in series to increase the operating voltage by plugging the positive plug of one module 
into the negative socket of the next. Before connecting modules always ensure that the contacts are corrosion free, 

Mounting rail 

4-

φ

9*12 installation hole 

4

Содержание TSM-DC01A.05

Страница 1: ...DC80 08 The Honey M Module TSM DC05A TSM DC05A 05 TSM DC05A 08 The Aesthetic Module TSM PC05 05 The Comax Module TSM DC01A TSM DC01A 08 The Universal Module TSM PC05 TSM PC05 08 The Utility Module TSM...

Страница 2: ...VIRONMENTAL CONSIDERATIONS 2 4 1 CLIMATE CONDITIONS 2 5 SITE SELECTION 2 6 MOUNTING INSTRUCTIONS 2 6 1 MOUNTING METHODS 2 A Mounting with Bolts 3 B Mounting with Clamps 3 6 2 GROUNDING 4 6 3 MODULE WI...

Страница 3: ...ity of each module or a string is not reversed considering the rest of the modules or strings Do NOT artificially concentrate sunlight on these solar modules Trina Solar modules are certified for oper...

Страница 4: ...ding at any time of the day Shading can normally be minimized by ensuring that the distance between the obstruction and solar array is greater than three times the obstruction s height Do not install...

Страница 5: ...imilar insulating washer fixing screw of at least M6 The clamp must overlap the module frame by at least 7mm but no more than 10 mm Use at minimum 4 clamps to fix modules on the mounting rails Modules...

Страница 6: ...nding conductor The grounding conductor or strap may be copper copper alloy or any other material acceptable for use as an electrical conductor per respective National Electrical Codes The grounding c...

Страница 7: ...rray generates DC electricity whenever light falls on it similarly the inverter automatically turns ON as soon as there is sufficient energy from the solar array to efficiently convert this into grid...

Страница 8: ...the benefit of cleaning dirt and debris from the array is a trade off between the cost of the cleaning increased energy production as a result of this cleaning and the time for the re soiling of the...