![Trilogy Mentor XL Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/trilogy/mentor-xl/mentor-xl_user-manual_1162754078.webp)
Mentor XL
17.
SPECIFICATION
Note. All measurements are made assuming, where appropriate, that the various offsets controlled
from the front panel are set to zero unless otherwise stated. All signal measurements are made with
inputs and outputs terminate
d in 75Ω
unless otherwise stated.
17.1
G
ENERAL
Width
19” rack mounting
Height
44 mm (1U)
Depth
433 mm (excluding connectors)
Weight
4kg, no option boards
5kg max. with option boards
Operating temperature range
0 to 50
°
C
Storage temperature range
-25 to 70
°
C
Operating humidity
95%RH non-condensing
17.2
EMC
Emissions
EN55103-1, Environment E2
Radiated
EN55103-2, Environment E2
Safety
EN60950
NOTE: Immunity is specified to criterion B - the outputs may suffer some degradation during the
disturbance, but will recover on removal of the disturbance source and continue to operate as
intended.
17.3
P
OWER
Mains input x 2
90-264 VAC, 45-63Hz, auto select
Power consumption
60VA max. (depending on number
of option boards fitted)
Internal Fuse
3.15A
17.4
I
NTERNAL
R
EFERENCE
O
SCILLATOR
S
TABILITY
Nominal error
<
±
0.5Hz (0.1ppm)
Temperature stability
(over operating temperature range)
< ±0.05ppm
Ageing rate (per year)
< 0.5ppm
Warm up settling time to <0.05ppm
10 minutes @ 25°C