![Trilogy Mentor XL Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/trilogy/mentor-xl/mentor-xl_user-manual_1162754077.webp)
Mentor XL
16.3
D
AYLIGHT
S
AVING
T
IME
Mentor XL has an automatic daylight saving time adjustment feature. To enable this from the front
panel controls, go to:
1.
Setup >> More >> RTC Setup >> Time zone
2.
Select your locale from the list and press OK to confirm
The real-time clock will now automatically adjust at the start and end of daylight saving time.
However, to ensure continuity, timecode will not change until Jam! occurs. For more information on
the different Jam modes available, please see section 11.1.
16.4
VITC
AS A
J
AM
!
S
OURCE
The 360-14-00 Timecode feature is required for this mode. DVITC, ATC and LTC are optionally able to
Jam to VITC on a genlock input. VITC input timecode lock is activated from the front panel menus as
follows:
•
Setup >> Timecode >> All Frequencies >> JAM Source >> VITC
•
Setup >> Timecode >> All Frequencies >> JAM! >> OK
Upon jamming, the VITC on the genlock input is sampled and all timecode outputs are updated.
Timecode outputs then increment from this point, until another Jam! is initiated. If the Mentor XL is
genlock referenced and is set to output the same frame rate as the genlock input, then timecode will
remain locked to the genlock input.
If the input genlock VITC changes, the Mentor will require a Jam! to reflect this change. This ensures
continuity of output timecode.