Seeker D User’s Guide
Document Num., Rev. 4
May 2018
Page 58
3. Confirm the Seeker is in the RF Level Measurement mode
The Antenna icon on the display should be flashing for the RF Level Measurement
mode. If necessary use the
SELECT
button
to move to the Measurement mode.
4. Begin leakage testing
Move the Seeker D around the test area. If the detected leakage level exceeds the
squelch level (default 2 mV/m), the Seeker D will alarm.
The frequency of the alarm tone will increase as the detected signal strength increases.
Continue to move the Seeker D in the direction producing the highest tone frequency to
locate the source of the leak.
5. Turn OFF the Seeker D
When testing is complete, turn off the Seeker D by holding down the red
ON/OFF
button
until you hear 3 descending tones. This step is not required if you leave the Seeker D in
the Mobile Mount.